首页> 外文期刊>AJNR. American journal of neuroradiology >Embolization of intracranial aneurysms with HydroSoft coils: results of the Korean multicenter study.
【24h】

Embolization of intracranial aneurysms with HydroSoft coils: results of the Korean multicenter study.

机译:HydroSoft弹簧圈栓塞颅内动脉瘤:韩国多中心研究的结果。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: Various modifications of detachable coils have been attempted to reduce recurrence rates in aneurysmal coil embolization and HydroSoft coil is one of them. The authors report their experience using HydroSoft coils in the treatment of cerebral aneurysms. MATERIALS AND METHODS: The present study is a prospective multicenter observational series of 127 aneurysms in 120 patients treated with HydroSoft coils. RESULTS: Ten centers participated in this study, and there were 92 (72%) unruptured and 35 ruptured aneurysms. Aneurysm volumes were >/= 100 mm(3) in 21 (17%) and < 100 mm(3) in 106 (83%) (mean, 56 mm(3); range, 5-249 mm(3)). The average percentage length of HydroSoft coils detached in treated aneurysms was 67% (range, 42%-100%). Immediate postprocedural angiography demonstrated complete aneurysm occlusion in 69% (87/127 aneurysms), residual neck in 20% (25/127), and residual sac in 12% (15/127). Procedure-related adverse events occurred in 4.7% (6/127 aneurysms), including procedural bleeding (5/127) and thromboembolism (2/127), and immediate procedure-related morbidity and mortality rates were 0.8% and 0%. Conventional angiography or MRA follow-up was performed in 83% (105/127) at >/= 6 months after treatment (mean interval, 11 months; range, 6-24 months). The overall recanalization rate was 3% (3/105 aneurysms; 2 major and 1 minor recanalizations). Progression to complete aneurysmal occlusion was noted in 20 of 27 aneurysms (74%) during the follow-up. CONCLUSIONS: The safety profile of HydroSoft coils appears acceptable. In terms of initial occlusion rates and durability, embolization by using HydroSoft coils seems to be favorable compared with most large series of pure platinum or coated coils.
机译:背景和目的:已经尝试了对可拆卸线圈的各种修改,以降低动脉瘤线圈栓塞的复发率,并且HydroSoft线圈就是其中之一。作者报告了他们使用HydroSoft线圈治疗脑动脉瘤的经验。材料与方法:本研究是对120例接受HydroSoft线圈治疗的患者的127个动脉瘤的前瞻性多中心观察系列。结果:十个中心参加了这项研究,有92(72%)破裂和35破裂的动脉瘤。动脉瘤体积在21(17%)中> / = 100 mm(3),在106(83%)中<100 mm(3)(平均56 mm(3);范围5-249 mm(3))。在治疗的动脉瘤中脱落的HydroSoft卷材的平均百分比长度为67%(范围为42%-100%)。术后立即进行的血管造影显示完全闭塞的动脉瘤占69%(87/127动脉瘤),残余颈动脉占20%(25/127),残余囊占12%(15/127)。与手术相关的不良事件发生率为4.7%(6/127动脉瘤),包括程序性出血(5/127)和血栓栓塞(2/127),即时与手术相关的发病率和死亡率分别为0.8%和0%。在治疗后6个月(平均间隔11个月;范围6-24个月)中,有83%(105/127)的患者接受了常规血管造影或MRA随访。总体再通率为3%(3/105动脉瘤; 2次主要和1次次再通)。在随访期间,在27个动脉瘤中有20个(74%)观察到进展为完全动脉瘤闭塞。结论:HydroSoft卷材的安全性似乎是可以接受的。在初始吸留率和耐用性方面,与大多数大系列的纯铂金或镀层线圈相比,使用HydroSoft线圈进行栓塞似乎是有利的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号