首页> 外文期刊>X-Ray Spectrometry: An International Journal >Valence-to-core X-ray emission spectroscopy of Ti, TiO, and TiO2 by means of a double full-cylinder crystal von Hamos spectrometer
【24h】

Valence-to-core X-ray emission spectroscopy of Ti, TiO, and TiO2 by means of a double full-cylinder crystal von Hamos spectrometer

机译:借助于双全圆柱水晶伏摩斯光谱仪,Ti,TiO和TiO2的价核X射线发射光谱法

获取原文
获取原文并翻译 | 示例
           

摘要

We present valence-to-core X-ray emission spectroscopy of Ti, TiO, and TiO2 by means of a double crystal von Hamos spectrometer based on full-cylinder highly annealed pyrolytic graphite mosaic crystals. We demonstrate that, using a double crystal configuration, an energy resolution of E/Delta E approximate to 2,700 can be achieved in a compact setup using cylindrically curved optics with a radius of curvature of 50 mm. The stated energy resolution proved to be high enough to identify and determine chemical shifts of the K beta(2,5) and K beta '' emission lines of both oxides. The experimental results are supported by calculations with the ab initio package OCEAN and compared with literature values.
机译:我们通过基于全缸高压退火的热解石墨镶嵌物晶体的双晶von滨水光谱仪呈现Ti,TiO和TiO2的价X射线发射光谱仪。 我们证明,使用双晶配置,可以在使用圆柱形弯曲的光学的紧凑型光学的紧凑型弯曲光学的紧凑型设置下实现e / delta e的能量分辨率,其曲率半径为50mm。 所规定的能量分辨率被证明足够高,以鉴定和确定两种氧化物的kβ(2,5)和kβ'发射线的化学位移。 使用AB Initio包海洋的计算支持实验结果,并与文献值进行比较。