首页> 外文期刊>Transactions of The Institution of Chemical Engineers. Process Safety and Environmental Protection, Part B >Experimental investigation of particle deposition in filter media during filtration cycles with regeneration by pulse jet cleaning
【24h】

Experimental investigation of particle deposition in filter media during filtration cycles with regeneration by pulse jet cleaning

机译:过滤介质粒子沉积在过滤循环中脉冲射流清洁再生液中粒子沉积的实验研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The objective of this study was to experimentally evaluate the influence of particle deposition on gas filtration with pulse jet cleaning. Filtration experiments were performed using dolomitic limestone particles, with polyester and polypropylene filter media. A total of 100 filtration tests were performed with a surface velocity of 4 cm/s. The stipulated maximum pressure drop was 1000 Pa, the pulse time was 200 ms, and the pulse pressure was 200 kPa. After 100 filtration cycles, the polyester filter presented higher cleaning efficiency, higher collection efficiency, lower particle retention, higher permeability, lower residual pressure drop, and lower mass retained after reverse air pulse cleaning, compared to the polypropylene filter. The results confirmed that the polyester filter presented excellent operational performance when pulse jet cleaning was used. Furthermore, surface filtration was more pronounced for the polyester filter, due to lower deposition of particles inside the filter. (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
机译:本研究的目的是通过脉冲喷射清洁进行实验评估粒子沉积对气体过滤的影响。使用多粒石灰石颗粒,具有聚酯和聚丙烯过滤介质进行过滤实验。通过4cm / s的表面速度进行总共100个过滤试验。规定的最大压降为1000Pa,脉冲时间为200ms,脉冲压力为200kPa。在100次过滤循环后,与聚丙烯过滤器相比,聚酯过滤器呈现较高的清洁效率,更高的收集效率,更低的颗粒保留,更高的渗透率,较低的残余压降和较低的质量。结果证实,当使用脉冲射流清洁时,聚酯过滤器呈现出优异的操作性能。此外,由于过滤器内的颗粒沉积较低,对聚酯过滤器更加明显表面过滤。 (c)2019化学工程师机构。 elsevier b.v出版。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号