Whole slide imaging (WSI) uses robotic microscopes for computerising entire slides into digital images. The aim of this study was to assess the agreement between WSI and optical microscopy for evaluating canine lymphoma cytological samples. Forty-four slides were computerised using a WSI scanner and the digital and glass slides were examined by three observers with different levels of expertise. Morphology and grade of lymphoma were scored on the basis of the updated Kiel classification and intra-observer agreement was assessed. The accuracy of determining the grade of lymphoma with digital and glass slides based on the results of flow cytometry (FC) was established. The overall intra-observer agreement for cytomorphological features was fair to moderate (kappa = 0.34-0.52) for the three observers and moderate (kappa = 0.44-0.53) for the evaluation of grade of malignancy. The diagnostic agreement between FC and digital slides was slight (kappa = 0.16) for the inexperienced observer, fair (kappa = 0.32) for the mildly experienced observer and moderate (kappa = 0.50) for the very experienced observer. The diagnostic agreement between FC and glass slides was fair (kappa = 037) for the inexperienced observer, substantial (kappa = 0.63) for the mildly experienced observer and moderate (kappa = 0.50) for the very experienced observer. These findings underline the importance of observer experience in determining the grade of malignancy, especially if digital slides are used. The study also identifies some technical limitations of the WSI scanner used in this study, mainly linked to image quality, which might affect the morphological evaluation of neoplastic cells. (C) 2018 Elsevier Ltd. All rights reserved.
机译:整个幻灯片成像(WSI)使用机器人显微镜用于将整个幻灯片计算机化为数字图像。本研究的目的是评估WSI与光学显微镜之间的协议,用于评估犬淋巴瘤细胞学样品。使用WSI扫描仪计算机化四十四个幻灯片,并通过三个观察者进行数字和玻璃载玻片,其中三个观察者具有不同的专业知识。根据更新的基尔分类,评估了淋巴瘤的形态和等级,并评估了观察员内部的协议。建立了基于流式细胞术(FC)的数字和玻璃载玻片的淋巴瘤等级的准确性。对于三个观察者和中度(Kappa = 0.44-0.53)来评估恶性肿瘤等级,对细胞形态特征的总体观察组织特征达成公平是公平的(Kappa = 0.34-0.52)。对于非常经验丰富的观察者和中等(Kappa = 0.50)的缺乏经验的观察者,FC和数字幻灯片之间的诊断协议是轻微的(Kappa = 0.16),适用于非常经验丰富的观察者的观察者和中度(κ= 0.50)。对于缺乏经验的观察者而言,FC和玻璃载玻片之间的诊断协议是公平的(Kappa = 037),对于非常经验丰富的观察者,适用于温和的观察者的实质性(Kappa = 0.63),非常有效的观察者和中等(Kappa = 0.50)。这些发现强调了观察者经验在确定恶性等级方面的重要性,特别是如果使用数字幻灯片。该研究还确定了本研究中使用的WSI扫描仪的一些技术限制,主要与图像质量相关联,这可能影响肿瘤细胞的形态学评估。 (c)2018年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号