首页> 外文期刊>The Prostate >The impact of diurnal variation of PSA on timing of measurement in prostate biopsy
【24h】

The impact of diurnal variation of PSA on timing of measurement in prostate biopsy

机译:PSA差异变异对前列腺活检测量时间的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background Prostate‐specific antigen (PSA) synthesis is related to testosterone, which has a diurnal rhythm. PSA might have a diurnal variation and the timing of measurement could change the clinical practice for prostate biopsy. Methods Male patients complaining of lower urinary tract symptoms (group 1) and diagnosed with prostate cancer (group 2) were recruited into the study. Morning fasting blood samples were withdrawn between 9.00 and 11.00 am for the determination of biochemical parameters, PSA (PSA1), total testosterone (T1), and estradiol (E1) levels. In the afternoon, between 15.00 and 15.30 pm , blood samples were again obtained from the same participants at the same day and the serum concentration of PSA (PSA2), total testosterone (T2), and estradiol (E2) were measured. Results A total of 160 and 30 patients were enrolled in groups 1 and 2, respectively. One hundred forty (87.5%) and 26 (86.6%) patients had a decrease in the PSA levels when measured in the afternoon. The Wilcoxon signed‐rank test determined a statistically significant difference between the PSA levels measured in the morning and in the afternoon in each group. An analysis of covariance test revealed no statistically significant difference in PSA concentration between the groups after adjustment for baseline concentration (F(1.187)?=?0.203, P ?=?.653). There was a weak positive correlation between PSA1/PSA2 and T1/T2, r s (160)?=?0.163, P ?=?.034. An extra unit increase in PSA1 concentration leads to a 0.805 (95% confidence interval [CI], 0.781‐0.830) and 0.828 (95% CI, 0.807‐0.849) ng/mL increase in PSA2 concentration in groups 1 and 2, respectively, that is, patients with and without prostate cancer had a similar decrease in the PSA levels. When measured in the afternoon, 66.6% and 50% patients with a morning PSA level over 3 or 4?ng/mL had a PSA drop below these levels, respectively. Conclusions PSA has a diurnal variation and the timing of measurement may alter the decision of the clinician for transrectal ultrasound prostate biopsy.
机译:摘要背景前列腺特异性抗原(PSA)合成与睾酮有关,睾酮具有昼夜节律。 PSA可能具有昼夜变化,测量的时序可以改变前列腺活组织检查的临床实践。方法携带抱怨低尿路症状(第1组)和诊断前列腺癌(第2组)的男性患者被招募到该研究中。早晨禁食血液样品在9.00至11.00 AM之间取出,用于测定生物化学参数,PSA(PSA1),总睾酮(T1)和雌二醇(E1)水平。在下午,下午15点和15.30点之间,测量从同一天从相同的参与者获得血液样品,并测量PSA(PSA2),总睾酮(T2)和雌二醇(E2)的血清浓度。结果共有160例和30名患者分别注册第1组和第2组。一百四十(87.5%)和26例(86.6%)患者在下午测量时PSA水平减少。 Wilcoxon签名 - 秩检验确定了在每组早晨测量的PSA水平与每组下午之间的统计学显着差异。对协方差测试的分析显示基线浓度调整后基团之间的PSA浓度的统计学上显着差异(F(1.187)?=Δ0.203,p?=α.653)。 PSA1 / PSA2和T1 / T2,R S(160)之间存在弱的正相关性,(160)?= 0.163,P?= 034。额外的单位增加PSA1浓度导致0.805(95%置信区间[CI],0.781-0.830)和0.828(95%CI,0.807-0.849),分别在1和2组中PSA2浓度增加,也就是说,患有和没有前列腺癌的患者的PSA水平的降低。当在下午测量时,66.6%和50%的患者早晨PSA水平超过3或4μg/ ml,分别在这些水平以下PSA下降。结论PSA具有昼夜变化,测量的时机可能会改变临床医生对癌症超声前列腺活检的决定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号