Abstract Objectives Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. Methods We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. Results The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. Conclusion We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination.
机译:摘要目标尿显微镜是在急诊部门(EDS)中进行的常用测试。尿标本可以容易地被不同因素污染,包括收集方法。中游清洁捕获(MSCC)采集技术通常用于减少尿污染。我们ED中收集的标本的尿培养污染率为30%。我们开发了一个教学应用程序(APP),以显示ED患者如何提供MSCC尿液样本。我们假设观看我们的教学应用程序的ED患者与没有的患者相比,尿液污染率明显降低。方法我们在ED中纯分析了257名受试者,尿液分析和/或尿培养检验,并要求他们观看我们的MSCC教学应用程序。在预期注册完成后,我们回顾性地匹配每次注册的受到没有观看教学应用程序的患者。控制与基于性别,提供的尿样类型的案例相匹配,参观日期和转移。使用McNemar测试比较靶尿液分析和尿培养污染结果。结果514项受试者的总尿培养污染率为38%。大多数匹配对具有尿液分析(63%)或尿液分析加尿培养(35%)测试。通过先前了解干净的捕获过程或尿样的尿样,匹配对与性别分层的匹配对之间的尿液污染速率没有显着差异。结论与未完成的患者相比,我们没有看到患者的患者污染率较低。 MSCC可能对降低尿标本污染无效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号