首页> 外文期刊>The Journal of perinatal & neonatal nursing >Efficacy of Vein Visualization Devices for Peripheral Intravenous Catheter Placement in Preterm Infants
【24h】

Efficacy of Vein Visualization Devices for Peripheral Intravenous Catheter Placement in Preterm Infants

机译:静脉可视化装置对早产儿外周静脉导管的功效

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this randomized controlled trial was to examine the efficacy of vein visualization devices and the routine method for insertion of peripheral intravenous catheters (PIVCs) in preterm infants. The study was conducted between June 2016 and April 2017 in the neonatal intensive care unit of Bak?rk?y Dr Sadi Konuk Education and Research Hospital. Participants ( N = 90) were randomly assigned to the infrared group ( n = 30), the transilluminator group ( n = 30), or the control group ( n = 30). Time to successful cannulation was significantly lower for the infrared group (8.70 ± 2.56 seconds) than for the transilluminator group (45.27 ± 30.83 seconds) and the control group (17.30 ± 8.40 seconds) ( P ≤ .001). Success of the first attempt was significantly higher in the infrared and transilluminator groups than in the control group ( P ≤ .05). Dwell time of the PIVC in place was significantly higher in the infrared group than in the transilluminator and control groups ( P ≤ .05). Neonatal Infant Pain Scale scores were significantly higher in the transilluminator group (0.60 ± 0.855) than in the infrared (0.33 ± 0.182) and control groups (0.33 ± 0.182) while seeking an appropriate vein ( P ≤ .001). The use of an infrared device provides efficacy in time to successful cannulation, success of the first attempt, length of the time the catheter is in place, and technique-related pain.
机译:这种随机对照试验的目的是检查静脉可视化装置的功效和预防早产儿插入外周静脉内导管(PIVC)的常规方法。这项研究于2016年6月至2017年4月在Bak新生儿重症监护单位之间进行了?rk?Y Sadi Konuk教育和研究医院博士。将参与者(n = 90)随机分配给红外组(n = 30),过敏器基团(n = 30)或对照组(n = 30)。对于红外组(8.70±2.56秒)的成功插管的时间显着降低(45.27±30.83秒)和对照组(17.30±8.40秒)(p≤.001)。红外和过敏器组的第一次尝试的成功显着高于对照组(P≤05)。在红外组的PIVC的停留时间显着高于过敏器和对照组(P≤.05)。经荧光剂组(0.60±0.855)中的新生儿婴儿疼痛标度分数比红外(0.33±0.182)和对照组(0.33±0.182),同时寻找合适的静脉(P≤.001)。红外装置的使用在时间上提供功效以成功装载,第一次尝试的成功,导管到位的时间长度,以及技术相关的疼痛。

著录项

  • 来源
  • 作者单位

    Pediatric Nursing Department (Dr ?a?lar) and Fundamentals of Nursing Department (Dr Büyüky?lmaz);

    Pediatric Nursing Department (Dr ?a?lar) and Fundamentals of Nursing Department (Dr Büyüky?lmaz);

    Pediatric Nursing Department (Dr ?a?lar) and Fundamentals of Nursing Department (Dr Büyüky?lmaz);

    Pediatric Nursing Department (Dr ?a?lar) and Fundamentals of Nursing Department (Dr Büyüky?lmaz);