首页> 外文期刊>The Journal of molecular diagnostics: JMD >A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs
【24h】

A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs

机译:COBAS 4800 HPV,PapilloCheck HPV筛选和LMNX基因分型试剂盒HPV GP用于检测宫颈癌和宫颈癌拭子的人乳头瘤病毒DNA

获取原文
获取原文并翻译 | 示例
           

摘要

High-risk human papillomavirus (hrHPV) infection is a cause of cervical cancer development. The addition of hrHPV testing to cervical cancer screening and monitoring of cervical intraepithelial neoplasia treatment improves the efficacy of screening and treatment, respectively. Self-sampling for hrHPV testing seems a promising tool for increasing patient participation in cervical cancer screening. In this project, 1198 cervical swabs obtained by physicians and 176 cervicovaginal swabs obtained by self-sampling (not collected in parallel) were analyzed for the presence of 14 hrHPV genotypes using three commercially available assays in comparison. HPV DNA was detected in 21.2% of all samples (21% of cervical swabs and 22.7% of cervicovaginal swabs). The cobas 4800 HPV Test was the most sensitive (0.983) and specific (0.992) for hrHPV detection overall. The PapilloCheck HPV-Screening and LMNX Genotyping Kit HPV GP had comparable specificity with that of the cobas (0.989 and 0.955, respectively), but lesser sensitivity (0.897 and 0.909, respectively). In physician-obtained cervical swabs, the cobas showed the highest sensitivity and specificity (0.980 and 0.994, respectively) for hrHPV detection, whereas in cervicovaginal swabs, the cobas had the highest sensitivity (1.00), but the PapilloCheck had the highest specificity (0.993). In conclusion, all of the detection methods evaluated were highly sensitive and specific for hrHPV detection from both clinician-collected cervical swabs and self-sampled cervicovaginal swabs.
机译:高风险的人乳头瘤病毒(HRHPV)感染是宫颈癌发育的原因。向宫颈癌筛查和对宫颈上皮内瘤周期治疗的癌症筛查和监测的添加分别提高了筛选和治疗的疗效。 HRHPV测试的自我抽样似乎是增加患者参与宫颈癌筛查的有希望的工具。在该项目中,通过相比之下的三种商用测定,分析通过自抽样和176个通过自抽样(并行收集)获得的1198个宫颈拭子,通过三种商业上可获得的测定来分析14 HRHPV基因型的存在。在21.2%的所有样品(21%的宫颈拭子和22.7%的宫颈拭子)中检测到HPV DNA。 COBAS 4800 HPV测试是最敏感的(0.983),具体(0.992),总体而言,HRHPV检测。 PapilloCheck HPV筛选和LMNX基因分型试剂盒HPV GP具有可比特异性的特异性具有与COBAS(分别为0.989和0.955)的特异性,但敏感性较小(分别为0.897和0.909)。在医生所获得的宫颈拭子中,COBAS显示出最高的敏感性和特异性(分别为0.980和0.994)用于HRHPV检测,而在宫颈拭子拭子中,雪氏卵带具有最高的敏感性(1.00),但乳头复合物具有最高的特异性(0.993 )。总之,评估的所有检测方法对临床医生收集的宫颈拭子和自捕术宫颈拭子的HRHPV检测非常敏感和特异性。

著录项

  • 来源
  • 作者单位

    Palacky Univ Olomouc Fac Med &

    Dent Inst Mol &

    Translat Med Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Inst Mol &

    Translat Med Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Inst Mol &

    Translat Med Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Inst Mol &

    Translat Med Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Dept Biol Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Dept Obstet &

    Gynecol Olomouc Czech Republic;

    Arleta IVF Ltd Kostelec Nad Orlici Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Dept Obstet &

    Gynecol Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Dept Obstet &

    Gynecol Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Inst Mol &

    Translat Med Olomouc Czech Republic;

    Palacky Univ Olomouc Fac Med &

    Dent Inst Mol &

    Translat Med Olomouc Czech Republic;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 临床医学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号