Comparison of the Primary Stability of a Porous Coated Acetabular Revision Cup With a Standard Cup

机译:用标准杯对多孔涂层髋臼修正杯的初级稳定性的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background The number of revision hip arthroplasty procedures has been increasing substantially, with the acetabular component requiring component revision in over half of the cases. New porous implant designs attempt to improve outcomes due to improved osseointegration; however, sufficient primary stability is paramount for good osseointegration. Methods We compared 2 revision cups of the same geometry, yet different surface properties in an in?vitro scenario: a porous titanium surface and a conventional sintered-bead titanium surface. These were tested in 10 cadaveric pelvises under a physiologic cyclic partial weight-bearing scenario. Each side was randomly implanted with one of the implants. Relative motion between the bone and cup was measured using an optical measuring device. Statistical evaluation was carried out descriptively using a covariance analysis with repeated measures and a test of fixed effects, with significance determined as P Results The conventional cup displayed an average relative motion of 28.02 μm; and the porous implant displayed an average relative motion of 33.42 μm. There was no statistically significant difference between the two with regard to the resultant relative motion ( P ?= .2649). The bone mineral density does have a significant influence on resultant relative motion ( P ?= .0406), with higher bone mineral density correlating with less relative motion in both implants. Conclusion The porous implant provides similar primary stability to the conventional implant in the tested scenario; the motion of both implants relative to the bone was within safe limits for osseointegration. Bone stock must be considered when choosing implant type and postoperative care.
机译:摘要背景髋关节关节置换术手术的次数大幅增加,髋臼组分需要在其中一半的病例中需要组分修订。新的多孔植入物设计试图改善由于骨整合的改善而改善结果;然而,对于良好的骨整合,足够的主要稳定性是至关重要的。方法采用相同的几何形状的2个修正杯,但在体外情景中的不同表面特性:多孔钛表面和常规烧结珠钛表面。这些在10个尸体瓣膜下在生理循环部分负重方案下进行测试。每侧随机植入其中一个植入物。使用光学测量装置测量骨骼和杯之间的相对运动。通过重复措施的协方差分析和固定效应的测试来描述统计学评估,并且由于P结果确定了传统杯28.02μm的平均相对运动的重要性。多孔植入物显示出33.42μm的平均相对运动。两个关于所得相对运动的统计学上有显着差异(P?= .2649)。骨矿物密度对所得到的相对运动(p≤= .0406)产生显着的影响,具有较高的骨矿物密度与两种植入物中相对运动的相对运动较低。结论多孔植入物在经过测试的情况下为常规植入物提供了类似的主要稳定性;两种植入物相对于骨骼的运动是骨整合的安全限制。选择植入物类型和术后护理时,必须考虑骨头库存。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号