THE CORROSION characteristics of cobalt alloy, Co-35 Ni-20 Cr-10 Mo, with different cold worked conditions have been studied systematically under simulated body fluid conditions with a view to determining the suitable condition/treatment under which the alloy exhibits good corrosion resistance. Breakdown potential, pitting/crevice corrosion resistance, and the ability to form protective oxide scales were evaluated and compared. The advantages of as-annealed cobalt alloy over other cold-worked conditions are highlighted. A-C impedance measurements were also carried out in order to provide supportive evidence for the above results. The advantages of using titanium alloys over other materials are also mentioned. Finally, the importance of alloy selection for biomedical applications is emphasized.
机译:在模拟的体液条件下,系统研究了钴合金Co-35 Ni-20 Cr-10 Mo在不同冷加工条件下的腐蚀特性,以确定合适的条件/处理方法,使合金具有良好的耐腐蚀性。 。评估并比较了击穿电位,耐点蚀/缝隙腐蚀和形成保护性氧化皮的能力。强调了退火后的钴合金相对于其他冷加工条件的优势。还进行了A-C阻抗测量,以为上述结果提供支持证据。还提到了使用钛合金优于其他材料的优点。最后,强调了在生物医学应用中选择合金的重要性。