Effects of pH and concentration of sodium citrate anticoagulant on platelet aggregation measured by light transmission aggregometry induced by adenosine diphosphate

机译:用腺苷二磷酸盐诱导的光透射聚集体测量柠檬酸钠抗凝剂钠对血小板聚集的影响

获取原文
获取原文并翻译 | 示例

摘要

The 2013 ISTH-SSC guidelines for the standardization of light transmission aggregometry (LTA) were largely based on expert consensus, as studies directly comparing LTA methodologies were lacking. We experimentally tested the cogency of ISTH-SSC recommendations pertaining to use of anticoagulant, in particular whether: (1) buffered citrate (BC) is preferable to unbuffered citrate (C); (2) the two recommended concentrations of sodium citrate (109 and 129 mM) are equivalent in terms of platelet aggregation (PA). Blood from 16 healthy volunteers was collected into BC and C (109 and 129 mM). PA was measured by LTA in platelet-rich plasma (PRP) stimulated by adenosine diphosphate (ADP) (2 M) immediately after PRP preparation and up to 4 hr after blood collection; pH and platelet counts in PRP were measured in parallel. pH in PRP increased with time up to about 8 for all anticoagulants, although it was lower in BC than in C at all times. In BC, PA was lower at 45 min, but equivalent at all other times. PA was higher and more stable in sodium citrate 109 mM than in 129 mM at all times. The extent of PA did not change for up to 2 hr after blood collection, and subsequently dramatically decreased. In contrast with ISTH-SSC recommendations, (1) BC does not show advantages compared to C; (2) 109 mM citrate is preferable to 129 mM, because it better supports PA; and (3) LTA studies should be completed within 2 hr of blood collection, instead of the recommended 4 hr.
机译:2013年的光传输聚合物(LTA)标准化的2013年ISTH-SSC指南主要基于专家共识,因为缺乏直接比较LTA方法的研究。我们通过实验测试了与抗凝血剂的使用的ISTH-SSC建议的核心,特别是:(1)是否优选进行缓冲的柠檬酸盐(C); (2)在血小板聚集(PA)方面,柠檬酸钠(109和129mm)的两个推荐浓度是等同的。收集来自16个健康志愿者的血液,进入BC和C(109和129 mm)。 PA通过LTA在PRP制剂后立即通过腺苷二磷酸(ADP)(2M)刺激的富含血小板血浆(PRP)的血浆(PRP)测量,血液收集后高达4小时; PRP中的pH和血小板计数并行测量。所有抗凝血剂的PRP在PRP中增加了大约8的时间,尽管在BC始终比C次较低。在BC,PA在45分钟后较低,但在所有其他时期相当。 PA始终比柠檬酸钠更高,柠檬酸钠更稳定,始终比129毫米。 PA的程度在血液收集后没有最多2小时改变,随后显着减少。与ISTH-SSC建议相比,(1)BC与C相比没有显示出优势; (2)柠檬酸盐的109mm柠檬酸盐优选为129毫米,因为它更好地支持PA; (3)LTA研究应在血液收集2小时内完成,而不是推荐的4小时。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号