首页> 外文期刊>Blood coagulation & fibrinolysis: an international journal in haemostasis and thrombosis >Evaluation of coagulation stages of hemorrhaged swine: comparison of thromboelastography and rotational elastometry.
【24h】

Evaluation of coagulation stages of hemorrhaged swine: comparison of thromboelastography and rotational elastometry.

机译:出血猪凝血阶段的评估:血栓弹力图和旋转弹性测定法的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Thromboelastography (TEG) or rotational thromboelastometry (ROTEM) assesses blood viscoelastic properties and clotting kinetics that can be measured by Haemoscope TEG and Pentapharm ROTEM devices using slightly different methodologies. These devices were compared by measuring blood samples associated with various degrees of coagulopathy. Blood samples, collected from swine undergoing three types of severe injury and resuscitation protocol resulting in normal, hypercoagulopathy, and hypocoagulopathy, were assessed with TEG or ROTEM before the surgical procedures, and after injury, fluid resuscitation, and simulated hospital phase. Standard clotting parameters were compared by Student's t-test at a significance of a P value less than 0.05. Regression analysis indicated a positive correlation between TEG and ROTEM for reaction time (R), clotting rate (K), and maximum amplitude (Ma) parameters. With samples of normal coagulation, R (440 +/- 136 vs. 391 +/- 73 s), K (99 +/- 39 vs. 81 +/- 20 s), and Ma (74 +/- 4 vs. 69 +/- 5 mm) were higher, whereas (alpha) (68 +/- 8 vs. 75 +/- 3 mm) was lower with TEG than ROTEM, respectively; a P value is less than 0.05. The magnitude of changes from baseline in hypercoagulable or hypocoagulable samples due to level of injury was equivalent with TEG and ROTEM indicating comparable use of the instruments. However, when samples were extremely hypocoagulopathic due to resuscitation fluid, the TEG values could not be readily determined. Overall, TEG readings were higher than ROTEM readings; this disparity between the two instruments was attenuated with hypercoaguable samples. Both devices yielded similar information regarding the status of coagulation related to trauma. Because of operating characteristics, the same instrument should be used for monitoring the same patient or study.
机译:血栓弹力描记术(TEG)或旋转血栓弹力测定法(ROTEM)评估血液粘弹性和凝血动力学,可以通过血液镜TEG和Pentapharm ROTEM设备使用略有不同的方法进行测量。通过测量与各种凝血病相关的血液样本对这些设备进行了比较。在手术之前,受伤后,进行液体复苏和模拟住院期间,使用TEG或ROTEM对从遭受三种严重伤害和复苏方案(导致正常,高凝病和低凝病)的猪中采集的血样进行TEG或ROTEM评估。通过学生t检验比较标准凝血参数,P值显着小于0.05。回归分析表明,TEG和ROTEM在反应时间(R),凝血速率(K)和最大幅度(Ma)参数之间呈正相关。对于正常凝结的样本,R(440 +/- 136 vs.391 +/- 73 s),K(99 +/- 39 vs.81 +/- 20 s)和Ma(74 +/- 4 vs.与ROTEM相比,TEG的α(69 +/- 5 mm)更高,而α(68 +/- 8 vs. 75 +/- 3 mm)更低; P值小于0.05。由于损伤程度,高凝或低凝样品的基线变化幅度与TEG和ROTEM相当,表明仪器的可比性。但是,当样品由于复苏液而极度低凝时,则无法轻易确定TEG值。总体而言,TEG读数高于ROTEM读数;两种仪器之间的这种差异被高凝样品减弱了。两种设备都产生了与创伤相关的凝血状态相似的信息。由于操作特性的原因,应使用同一台仪器监视同一名患者或研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号