首页> 外文期刊>Strabismus >Effect of Rigid Gas Permeable Contact Lenses on Nystagmus and Visual Function in Hyperopic Patients with Infantile Nystagmus Syndrome
【24h】

Effect of Rigid Gas Permeable Contact Lenses on Nystagmus and Visual Function in Hyperopic Patients with Infantile Nystagmus Syndrome

机译:刚性透气隐形眼镜对婴儿眼压症综合征高渗患者眼球菌和视觉功能的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To determine the effect of rigid gas permeable contact lenses (RGPCL) on involuntary eye movements and visual function in hyperopic patients with infantile nystagmus syndrome. Methods: This prospective interventional case series was conducted on 16 patients with infantile nystagmus and hyperopia equal or more than +0.5 D and astigmatism more than -1 D over a 2-year period. A complete ophthalmological examination including determination of best corrected visual acuity (BCVA), contrast sensitivity, and videonystagmography was performed for all patients before and after at least 3 months of RGPCL use, and the outcomes were compared. Results: Thirty-two eyes of 16 patients with mean age of 18.6±4.9 years were enrolled. Mean spherical equivalent refractive error was +1.5±2.35 (range +1 to +6.25) diopters (D); corresponding values were +2.45±2.44 D (range +0.5 to +7.5) for spherical error and +1.90±0.83 D (range +1 to +4) for astigmatism. Monocular BCVA improved from 0.56±0.23 to 0.51 ±0.23 Log MAR (P=0.007), and binocular BCVA improved from 0.54±0.25 to 0.48±0.24 Log MAR (P=0.01) after fitting RGPCL. Following the use of RGPCL, contrast sensitivity was significantly improved at low (P=0.02) and intermediate (P< 0.001) frequencies but not at high frequencies (P=0.6). The frequency, amplitude, and intensity of nystagmus were decreased significantly after RGPCL use (P<0.001). Conclusion: RGPCL improved monocular and binocular BCVA and contrast sensitivity in hyperopic patients with infantile nystagmus syndrome. Motor indices of nystagmus (frequency, amplitude, and intensity) were also significantly improved after RGPCL use.
机译:目的:确定刚性气体透气隐形眼镜(RGPCL)对婴儿眼球菌综合征的远程患者的无意识眼动词和视觉功能的影响。方法:这一前瞻性介入案例系列是在16名婴儿眼球菌和远视患者中进行的,超过+0.5d,散光超过-1 d超过-1 d。完整的眼科检查,包括确定最佳矫正视力(BCVA),对比敏感度和videoMstagmography的所有患者在RGPCL使用之前和之后的所有患者进行,并比较结果。结果:16名患者的32只平均年龄为18.6±4.9岁的眼睛。平均球形等效折射误差为+ 1.5±2.35(范围+1至+ 6.25)屈光度(D);相应的值为球面误差为+ 2.45±2.44d(范围+0.5至+7.5),用于散光+ 1.90±0.83d(范围+1至+4)。单眼BCVA从0.56±0.23提高到0.51±0.23 LOG MAR(P = 0.007),双目BCVA从0.54±0.25到0.48±0.24到0.48±0.24原木(P = 0.01)。在使用RGPCL之后,对比度敏感性在低(P = 0.02)和中间(P <0.001)频率下显着改善,但不在高频(P = 0.6)。在RGPCL使用后,眼球菌的频率,幅度和强度显着降低(P <0.001)。结论:RGPCL改善了婴儿眼压症综合征远远患者的单眼和双目BCVA和对比度敏感性。在RGPCL使用后也显着改善了眼球菌(频率,幅度和强度)的电动机索引。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号