首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >A dilute-and-shoot sample preparation strategy for new and used lubricating oils for Ca, P, S and Zn determination by total reflection X-ray fluorescence
【24h】

A dilute-and-shoot sample preparation strategy for new and used lubricating oils for Ca, P, S and Zn determination by total reflection X-ray fluorescence

机译:通过全反射X射线荧光的Ca,P,S和Zn测定新的和使用润滑油的稀释和射击样品制备策略

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

In this work, a dilute-and-shoot method was developed for Ca, P, S and Zn determination in new and used lubricating oil samples by total reflection X-ray fluorescence (TXRF). The oil samples were diluted with organic solvents followed by addition of yttrium as internal standard and the TXRF measurements were performed after solvent evaporation. The method was optimized using an interlaboratorial reference material. The experimental parameters evaluated were sample volume (50 or 100 mu L), measurement time (250 or 500 s) and volume deposited on the quartz glass sample carrier (5 or 10 mu L). All of them were evaluated and optimized using xylene, kerosene and hexane. Analytical figures of merit (accuracy, precision, limit of detection and quantification) were used to evaluate the performance of the analytical method for all solvents. The recovery rates varied from 99 to 111% and the relative standard deviation remained between 1.7% and 10% (n = 8). For all elements, the results obtained by applying the new method were in agreement with the certified value. After the validation step, the method was applied for Ca, P, S and Zn quantification in eight new and four used lubricating oil samples, for all solvents. The concentration of the elements in the samples varied in the ranges of 1620-3711 mg L-1 for Ca, 704-1277 mg L-1 for P, 2027-9147 mg L-1 for S, and 898-1593 mg L-1 for Zn. The association of TXRF with a dilute-and-shoot sample preparation strategy was efficient for Ca, P, S and Zn determination in lubricating oils, presenting accurate results. Additionally, the time required for analysis is short, the reagent volumes are low minimizing waste generation, and the technique does not require calibration curves. (C) 2017 Elsevier B.V. All rights reserved.
机译:在这项工作中,通过全反射X射线荧光(TXRF),在新的和使用润滑油样品中为Ca,P,S和Zn测定开发了稀释和芽法。将油样用有机溶剂稀释,然后加入钇作为内标,在溶剂蒸发后进行TXRF测量。该方法使用互联网参考材料进行了优化。评估的实验参数是样品体积(50或100μl),测量时间(250或500秒)和沉积在石英玻璃样品载体(5或10μl)上的体积。使用二甲苯,煤油和己烷来评估和优化它们。用于评估所有溶剂的分析方法的性能(准确性,精度,检测和定量极限)的分析图。回收率从99增加到111%,相对标准偏差保持在1.7%和10%之间(n = 8)。对于所有要素,通过应用新方法获得的结果与认证价值一致。验证步骤后,将该方法应用于八个新的和四种使用的润滑油样品中的Ca,P,S和Zn定量,适用于所有溶剂。样品中的元素的浓度在约30-3711mg L-1的范围内变化,对于p,2027-9147mg L-1的704-1277mg L-1,898-1593 mg L- 1 Zn。 TXRF与稀释和拍摄样品制备策略的关联对于润滑油中的Ca,P,S和Zn测定是有效的,呈现精确的结果。此外,分析所需的时间很短,试剂量较小,最小化浪费产生,并且该技术不需要校准曲线。 (c)2017 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号