首页> 外文期刊>Separation and Purification Technology >Reliability and efficiency of pollution removal during long-term operation of a one-stage constructed wetland system with horizontal flow
【24h】

Reliability and efficiency of pollution removal during long-term operation of a one-stage constructed wetland system with horizontal flow

机译:单级建造湿地系统长期运行期间污染污染的可靠性和效率

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The paper presents the results of a study of the reliability and efficiency of pollutant removal during long term operation of a one-stage constructed wetland system with horizontal flow. The flow rate of the wastewater treatment plant was 1.2 m(3) d(-1), during the research period. Physical and chemical analyses of raw wastewater and treated effluent were carried out in the years 1997-2010 (14 years). During this study period, 56 series of analyses were performed and 112 wastewater samples were collected. The average efficiencies of BOD5 (Biochemical Oxygen Demand), COD (Chemical Oxygen Demand) and TSS (Total Suspended Solids) removal in the investigated facility during the 14 years of its operation were respectively: 84.7%, 80.9%, and 62.4%. The average values of these parameters in the treated wastewater were significantly lower than the values deemed acceptable by relevant regulations in Poland. The reliabilities of the wastewater treatment plant, based on the Weibull reliability theory for acceptable values of pollution parameters in the effluent of the treatment plant, were as follows: BOD5 - 92%, COD - 98%, TSS - 90%. The conducted analysis showed that the operational reliability of the one-stage horizontal subsurface flow constructed wetland (HSFCW) over the operation period was insufficient according to the Polish standards. Improvement of the reliability of the analyzed system by introduction of additional purification elements, such as irrigated biological beds or a constructed wetland with vertical wastewater flow, was recommended. (C) 2017 Elsevier B.V. All rights reserved.
机译:本文介绍了在具有水平流动的一级构造湿地系统的长期运行期间污染物去除可靠性和效率的研究结果。在研究期间,废水处理厂的流速为1.2米(3)D(-1)。 1997 - 2010年(14岁)进行了原料废水和治疗废水的物理和化学分析。在该研究期间,进行了56系列分析,收集了112种废水样品。在其运作14年的调查设施中,BoD5(生化需氧量),COD(化学需氧量)和TSS(总悬浮固体)的平均效率分别:84.7%,80.9%和62.4%。处理废水中这些参数的平均值明显低于波兰相关法规所可接受的值。废水处理厂的可靠性,基于治疗厂的流出物中污染参数可接受的污染参数可接受值的可靠性,如下:BOD5 - 92%,COD-98%,TSS - 90%。所进行的分析表明,根据波兰标准,在操作周期内的一级水平地下流动构造的湿地(HSFCW)的操作可靠性不足。推荐改进分析系统的可靠性,推荐使用额外的净化元素,例如灌溉生物床或具有垂直废水流动的构造湿地。 (c)2017 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号