A Comparison of Refraction Defects in Childhood Measured Using Plusoptix S09, 2WIN Photorefractometer, Benchtop Autorefractometer, and Cycloplegic Retinoscopy

机译:使用PlusOptix S09,2win Photorefratometometer,Benchtop Autorefrometer测量儿童折射缺陷的比较

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To compare Plusoptix (Gmbh, Nuremberg, Germany), 2WIN (Adaptica, Padua, Italy), the benchtop refractometer (Auto-Kerato-Refractometer KR-8900; Topcon Co, Tokyo, Japan), and retinoscopy with regard to the consistencies. Materials and Methods: In our prospective study, 200 eyes of 100 patients were included. We analyzed the demographics and characteristics of the patients, the percentage of patients from whom measurements could not be obtained, the measurements from both patients' eyes of pupil diameter, spherical, cylindrical, axis, and spherical equivalence. Results: The mean age +/- SD was 7.8 +/- 4.5 years (range, 1-18 years). Pupil diameter measurements were found to be consistent (Cronbach's alpha value >0.8). The sphere and spherical equivalence measurements for both eyes were found to be consistent with each other in all apparatus (Cronbach's alpha value >0.8). However, consistency was found to be lower in cylindrical values and the Jackson cross-cylinder measurements at 0 degrees and 45 degrees axis were found to be inconsistent with each other (Cronbach's alpha value <0.8). Conclusions: While consistency was observed in all methods in terms of sphere and spherical equivalence, consistency dropped in cylindrical values and no consistency was observed in axis values. It is important to take this point into consideration, especially in axis measurements.
机译:目的:要比较PlusOptix(GmbH,Nuremberg,德国),2温(Adaptica,Padua,意大利),台式折射仪(自动角蛋白折射仪KR-8900; Topcon Co,Topcon Co,Tokyo,Japan),以及视网膜镜的视网膜检查。材料和方法:在我们的前瞻性研究中,包括100名患者的200只眼睛。我们分析了患者的人口统计和特征,从无法获得测量的患者的百分比,来自瞳孔直径,球形,圆柱形,轴和球形等值的患者眼睛的测量。结果:平均年龄+/- SD为7.8 +/- 4.5岁(范围,1-18岁)。发现瞳孔直径测量是一致的(Cronbach的alpha值> 0.8)。发现双眼的球体和球形等效测量在所有设备中彼此一致(Cronbach的alpha值> 0.8)。然而,发现一致性在圆柱形值中较低,并且杰克逊跨筒测量在0度和45度轴上被发现与彼此不一致(Cronbach的alpha值<0.8)。结论:虽然在球体和球形等当量方面,在所有方法中观察到一致性,但在圆柱形值下掉落的一致性,并且在轴值中观察到轴值。重要的是要考虑这一点,特别是在轴测量中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号