...
首页> 外文期刊>Orthodontics & craniofacial research >Effectiveness of nickel-titanium springs vs elastomeric chains in orthodontic space closure: A systematic review and meta-analysis
【24h】

Effectiveness of nickel-titanium springs vs elastomeric chains in orthodontic space closure: A systematic review and meta-analysis

机译:镍钛弹簧对正畸空间闭合中弹性链的有效性:系统评价和荟萃分析

获取原文
获取原文并翻译 | 示例

摘要

The aim of this study is to explore the effectiveness of nickel titanium closing springs (NiTi-CS) and elastomeric power chains (EPC) in orthodontic space closure and to assess the adverse periodontal effects, cost efficiency and patient-centred outcomes between both of these methods. Methods: An electronic search of online databases (Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Scopus, LILACS and Web of Science), reference lists and grey literature as well as hand search were conducted without language restriction up to November/2017. Two authors blindly and in duplicate were involved in study selection, quality assessment and the extraction of data. Only randomized clinical trials (RCTs) were included. The quality of the studies was assessed using the Cochrane Collaboration's risk of bias tool. 95% confidence intervals and mean difference for continuous data were calculated. A meta-analysis that generated a random-effect model for the comparable outcomes was conducted, and heterogeneity was measured using I-2 statistic. Results: Of 187 records, 4 RCTs met the criteria and were included in the quantitative synthesis featuring 290 test quadrants. Faster space closure with NiTi-CS was observed with a mean difference of (0.20 mm/month, 95% CI: 0.12 to 0.28). Loss of anchorage appears to be similar within both groups when synthesized qualitatively. With exception to anchorage loss, secondary outcomes could not be investigated in the included trials. Conclusions: There is a moderate quality of evidence suggesting a faster orthodontic space closure with the NiTi-CS when compared to EPC. A comparable amount of anchorage loss was observed regardless of the utilized method of space closure. Further high-quality RCTs with parallel-groups, reporting on the adverse effects and patient-centred values, are recommended.
机译:本研究的目的是探讨镍钛闭合弹簧(NITI-CS)和弹性体电链(EPC)在正畸空间闭合中的有效性,并评估这两者之间的不良牙周效应,成本效率和患者中心的结果方法。方法:电子搜索在线数据库(Cochrane Central of受控试验(中央),MEDLINE,EMBASE,SCOPUS,Lilacs和Web),参考列表和灰色文献以及手搜索,没有语言限制到11月/ 2017。盲目和重复两份的两位作者参与了学习选择,质量评估和数据的提取。仅包括随机临床试验(RCT)。使用Cochrane协作的偏置工具的风险评估研究的质量。计算出95%的置信区间和连续数据的平均差异。进行了对可比较结果产生随机效应模型的荟萃分析,并使用I-2统计测量异质性。结果:187条记录,4个RCT符合标准,并包含在具有290个测试象限的定量合成中。观察到使用NITI-CS的更快空间闭合,平均差异(0.20毫米/月,95%CI:0.12至0.28)。当定性合成时,锚固损失似乎相似。在锚定损失的例外情况下,在包括的试验中无法调查二次结果。结论:与EPC相比,有一个适度的证据表明在NITI-CS时,较快的正畸空间闭合。无论利用的空间闭合方法如何,都观察到了可比的锚固损耗。建议使用并行组的高质量RCT,报告不利影响和患者中心的值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号