Coke oven liquor is one of the most contaminated liquid streams generated by the coal processing industry,thus its proper treatment and utilization is crucial for sustainable and environmentally neutral plant operation.The conventional wastewater treatment process comprises of chemical and biological processes.Within the current research the detailed role of chemical treatment is described.Commercially available iron-based coagulants(PIX100,PIX100COP,PIX113,PIX116) were tested to understand their removal efficiency and impact on the stream parameters.The influence of iron dose in the range of 300-500 mgFe/L on the process performance was also examined.It was found that the main role of chemical treatment was to bind toxicants harmful to activated sludge microorganisms,i.e.free and complex cyanides and sulphides.Among the tested iron-based conventional coagulants ferrous salts were more efficient than ferric salts.It was also observed that efficiency of the process strongly depended on wastewater properties(especially in regard to pH,which should be in the range of 9-10) and the coagulant selection needed to be done individually for a given wastewater type.The removal rates of particular contaminants were diversified and for free cyanides,complex cyanides and sulphides they were in the range of 23-91%,-156-77% and-357-98%,respectively.The expected,simultaneous removal of chemical oxygen demand(COD) during the treatment was not observed and even the parameter value increased after the process due to probable formation of compounds less vulnerable to oxidation.
机译:焦炉液是煤加工行业产生的最污染的液体流之一,因此其适当的治疗和利用对于可持续和环境中性植物运作至关重要。传统的废水处理过程包括化学和生物过程。目前的研究测试了化学处理的详细作用。经过测试的是经过研发的铁基凝结剂(PIX100,PIX100cop,PIX113,PIX116)以了解其去除效率和对流参数的影响。铁剂量在300-500范围内的影响还研究了MGFE / L对过程性能进行了研究。发现化学处理的主要作用是将有害的污泥微生物有害的毒性作用,IEFREE和复合氰化物和硫化物。该经测试的铁基常规凝结剂含铁盐是比铁盐更有效。也观察到该过程的效率强烈依赖于此废水特性(特别是在pH值方面,应在9-10的范围内)和凝结剂选择需要单独进行给定的废水型。特定污染物的去除率多样化,用于自由氰化物,复合氰化物它们分别在23-91%的硫化物, - 156-77%和-357-98%。预期,同时除去治疗期间的化学需氧量(COD),甚至参数值由于可能的化合物的可能性而易受氧化的可能性而增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号