摘要

The Total Skin Electron Beam (TSEB) irradiation is a radiotherapeutic technique that aims to provide the patient's skin surface with a more homogeneous dose, in order to treat cutaneous T-cell lymphomas, both for curative and palliative purposes. Electron irradiation penetrates a few millimeters into the skin, reaching the affected parts completely, without penetrating the internal organs. In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. The LiF:Mg,Ti is the most used TL material and widely studied in radiotherapy dosimetry due to near tissue-equivalence of the material, along with its overall reliability. The dosimeters of mu LiF:Mg,Ti have been gaining considerable importance in the radiotherapy departments. These detectors allow measurements in vivo with great advantages due to their minimum dimensions of 1 x 1 x 1 mm(3). This paper reports a comparative study of the TL responses of both materials to dose evaluation in TSEB treatments. The TL response of both materials in several TSEB parameter tests and in clinical application were evaluated, analyzing the dose distribution in a treatment simulation using AldersonRando anthropomorphic phantom. The results showed that the mu LiF:Mg,Ti presented greater variation of the response in relation to LiF dosemeters in some parameters analyzed, due to the small dimensions and to evaluate doses absorbed in the surface over a large area in the treatment plan.
机译:总皮束(TSEB)辐射是一种放射治疗技术,其旨在向患者的皮肤表面提供更均匀的剂量,以便治疗皮肤T细胞淋巴瘤,两者都可以用于治疗和姑息的目的。电子照射渗透到皮肤上几毫米,完全到达受影响的部件,而不渗透内器官。在体内剂量测定中,在严格的质量保证计划内,在严格的质量保证计划中的治疗是一个重要的作用,应该是放射治疗部门的一个组成部分。在体内使用TLD可以识别规定剂量的变化,因为其测量精度和极高精度。 LIF:Mg,Ti是最常用的T1材料,并且由于材料的近似组织 - 当量而广泛地研究了放射疗法的剂量测定,其总体可靠性。 MU LIF的剂量计:MG,TI在放射治疗部门一直在越来越重要。这些探测器允许在体内测量,其最小尺寸为1×1×1mm(3)。本文报告了两种材料对TSE治疗剂量评估的TL反应的比较研究。评价两种材料在几种TSEB参数测试中和临床应用中的T1响应,分析了使用Aldersonrando拟人幽灵术治疗模拟中的剂量分布。结果表明,由于小尺寸,并且由于小尺寸,并且在治疗计划中的大面积上,μlif,ti在分析的一些参数中呈现与LiF剂量仪的响应相对于LiF剂量仪的更大变化。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号