Dosimetric impact of iodine content in a polyvinyl alcohol-iodide radiochromic gel dosimeter

机译:碘含量在聚乙烯醇 - 碘化物放射性胶质凝胶剂量计中的碘含量的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Recently, we developed a radiochmmic gel dosimeter based on a polyvinyl alcohol-iodide (PVA-I) complexes that can be reused after annealing. Although, the dosimeter is composed of water mostly, iodine was partially added. In the present study, the dosimeteric impact of iodine content in a PVA-I gel dosimeter was investigated through percentage depth dose (PDD) measurements using a flatbed scanner and Monte Carlo (MC) simulations. In addition, the PDD measurement was repeated 5 times by means of repeated annealing to evaluate repeatability of the dosimeter. In the gel dosimetry study, a good agreement was observed between the PDDs measured with the gel dosimeters with various iodine content, which were read out using a flatbed scanner, and the PDDs calculated with MC simulations in the dosimeters. Furthermore, a good repeatability of PDD(10) at 10 cm depth obtained from the repeated PDD measurements with the gel dosimeters was observed with less than 1% of standard deviation regardless of the iodine content. In the MC simulations, a good agreement was observed between the calculated PDDs in the gel dosimeters and the calculated PDDs in water. The photon fluence was significantly decreased as the iodine content was increased in the low-energy region unlike with the high-energy region. These results enabled us to conclude that the dose response with iodine content can be ignored in high-energy X-rays used in the field of radiotherapy. However, it might not be ignored in low-energy X-rays. Therefore, a small iodine content might be desirable for water-equivalent gel dosimeters.
机译:最近,我们开发了基于聚乙烯醇 - 碘化物(PVA-1)复合物的放射性凝胶剂量计,其可以在退火后重复使用。虽然,剂量计由水组成,但部分加入碘。在本研究中,通过使用平板扫描仪和蒙特卡罗(MC)模拟,通过百分比深度剂量(PDD)测量来研究PVA-I凝胶剂量计中碘含量的剂量计的影响。另外,通过重复的退火重复PDD测量5次以评估剂量表的可重复性。在凝胶剂量测定研究中,在用具有各种碘含量测量的PDD之间观察到良好的一致,其中使用平板扫描仪读出,并用剂量计中使用MC模拟计算的PDD。此外,从重复的PDD测量中获得的PDD(10)的良好可重复性,观察到与凝胶剂量计的重复的PDD测量值,无论碘含量如何,均低于1%的标准偏差。在MC仿真中,在凝胶剂量计中计算的PDD与水中计算的PDD之间观察到良好的一致性。由于碘含量在低能量区域与高能区不同,光子流量显着降低。这些结果使我们得出结论,在放射疗法领域的高能X射线中,可以忽略碘含量的剂量反应。但是,在低能量X射线中可能不会被忽略。因此,对于水当量的凝胶剂量计可能需要小碘含量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号