AbstractThe IAEA Dosimetry Laboratory (DOL) aims to improve the accuracy of clinical dosimetry in hospitals world-wide by providing independent remote audits for high energy photon beams. A thermoluminescent dosimetry (TLD) system has been used by the DOL to provide audit services for over 47 years. Two additional systems: an optically stimulated luminescent dosimetry (OSLD) system and a radiophoto luminescent dosimetry (RPLD) system underwent a commissioning process. The systems’ parameters, reading methodology and the dosimetric characteristics were investigated and compared.The read-out procedure for each system was established and optimized. Dosimetric characteristics such as reproducibility, signal fading with time after irradiation, signal per dose dependence and energy response were investigated. Additional tests to check signal depletion per readout and individual sensitivities of dosimeters were performed for RPLDs and OSLDs and also reading position dependence for the RPLD system was checked.The reproducibility of 4 readings of one dosimeter is 0.48% for TLDs, 0.16% for OSLDs and 0.15% for RPLDs. The fading effect after 100 days was 4% for TLD, 2% for OSLD and 0.4% for RPLD. Energy response of TLDs and RPLDs is comparable, higher corrections were found for OSLDs. The RPLD dose-response is sub-linear whereas TLD and OSLD response is supra-linear at the dose range under study (1–4?Gy). The TLD reading procedure is destructive but OSLDs and RPLDs can be read repeatedly and the signal depletion per reading is 0.036% for OSLDs and 0.0
机译:<![CDATA [ 抽象 原子能机构剂量测定实验室(DOL)旨在通过提供独立的方式提高全球医院临床剂量测定的准确性高能光子梁的远程审计。 DOL使用热敏发光剂量剂(TLD)系统以提供47岁以下的审计服务。另外两种系统:光学刺激的发光剂量测定法(OSLD)系统和辐射发光剂量(RPLD)系统接受调试过程。研究了系统的参数,读取方法和编号特征。 每个系统的读出过程是建立和优化。调查诸如再现性的剂量测定特性,用辐照后的时间褪色,每剂量依赖性和能量响应的信号褪色。对RPLD和OSLD执行每次读出的信号耗尽和单个敏感性的另外的测试是针对RPLD和OSLD进行检查,并且检查了RPLD系统的读取位置依赖性。 4个剂量表读数的再现性为TLD的0.48%,OSLD的0.16%,RPLDS为0.15%。 TLD 100天后的衰落效果为4%,欧联的2%和RPLD为0.4%。 TLD和RPLS的能量响应是可比的,对OSLD的校正较高。 RPLD剂量 - 响应是亚线性,而TLD和OSLD响应是在研究的剂量范围内的Supra-Linear(1-4?Gy)。 TLD读数程序是破坏性的,但可以重复读取OSLD和RPLD,并且每次读数的信号耗尽对于OSLDS和0.0

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号