Instead of using a set standard samples of irradiated tooth enamel, retrospective doses to tooth enamel can be estimated by ESR (electron spin resonance, or EPR) dosimetry with the spin numbers. The efficiency factor (the sensitivity to gamma ray dose) of the dosimetric CO2- ESR signal in tooth enamel was tentatively obtained, using a diluted tempol benzene solution, to be 8.73 x 10(16) spin/J (spin/kg/Gy), being equivalent to a G value (a spin number formed per 100 eV of absorbed energy) of 1.40. When a dosimetric system in a laboratory is calibrated with a standard with known spin numbers such as tempol, retrospective ESR tooth enamel ESR dosimetry is done without a set of irradiated tooth enamel standard samples.
机译:代替使用辐照牙釉质的设定的标准样品,通过ESR(电子自旋共振或EPR)剂量测定,可以通过具有旋转数的ESR(电子旋转共振或EPR)剂量来估计回顾性剂量。 使用稀释的Tempol苯溶液暂时获得牙釉质中的牙釉质中的剂量态CO2-ESR信号的效率因数(对γ射线剂量)的效率因数(γ射线剂量),为8.73×10(16)旋转/ J(Spin / Kg / Gy) ,相当于1.40的G值(由100eV形成的旋转数)为1.40。 当实验室中的剂量测定系统用具有已知旋转数的标准校准时,如Tempol,回顾性ESR牙釉质ESR剂量测定法没有一组辐射的牙釉质标准样品进行。