...
首页> 外文期刊>Respiratory care >Oscillating Positive Expiratory Pressure Therapy May Be Performed Poorly by Children With Cystic Fibrosis
【24h】

Oscillating Positive Expiratory Pressure Therapy May Be Performed Poorly by Children With Cystic Fibrosis

机译:囊性纤维化的儿童可以越来性地进行振荡正呼气压力疗法

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Oscillating positive expiratory pressure devices aid removal of excess secretions and reduce gas trapping in patients with hypersecretory pulmonary diseases, for example, cystic fibrosis. Oscillating positive expiratory pressure works when the patient exhales actively against a fixed resistor, which generates mean intrapulmonary pressures of 10-20 cm H2O with rapid fluctuations of at least 1 cm H2O from the mean. In this study, we evaluated the performance of oscillating positive expiratory pressure therapy by pediatric subjects with cystic fibrosis to determine adherence to target therapeutic pressures. METHODS: Twenty-one pediatric subjects were recruited. Each had a history of using an oscillating positive expiratory pressure device twice daily and had received standardized training and instructions from the same specialist physiotherapist. Performance was evaluated by using a flow and pressure sensor placed in-line between the participant's mouth and the device. The participants performed expirations as per their normal routine. RESULTS: None of the participants achieved target therapeutic pressure ranges during expiration. The mean +/- SD pressure generated was 16.2 +/- 6.8 cm H2O, whereas mean +/- SD flow was 31.3 +/- 8.9 L/min. The mean +/- SD expiration length was 2.5 +/- 1.4 s. CONCLUSIONS: Despite standardized instruction, the results demonstrated considerable variation among the participants and overall poor technique during use. Outcomes of this study indicated that airway clearance effects of oscillating positive expiratory pressure were compromised due to poor technique.
机译:背景技术:振荡正呼气压力装置辅助除去过量分泌物,减少患有过度肺疾病的患者的气体诱捕,例如囊性纤维化。当患者主动呼吸固定电阻器时振荡正呼气压力工作,这产生了10-20cm H2O的平均肺部压力,从平均值的快速波动。在这项研究中,我们评估了儿科受试者振荡正呼气压力疗法的性能,以确定依赖于靶治疗压力的依从性。方法:招募了二十一位儿科科目。每个人都有一个使用振荡的正呼气压力装置每天两次,并收到了来自同一专家物理治疗师的标准化培训和指示。通过使用参与者的嘴和设备之间的流量和压力传感器进行评估性能。参与者按照正常常规进行过期。结果:没有参与者在到期期间达到目标治疗压力范围。产生的平均+/- SD压力为16.2 +/- 6.8cm H 2 O,而平均值+/-SD流量为31.3 +/- 8.9 L / min。平均+/- SD到期长度为2.5 +/- 1.4 s。结论:尽管标准说明,结果表明参与者之间的相当大的变化以及在使用过程中的整体技术。本研究结果表明,由于技术差,振荡正呼气压力的气道清除效应受到损害。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号