首页> 外文期刊>Radiological physics and technology >Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer
【24h】

Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer

机译:技术说明:在肺癌中传统放疗中患者设置精度的改进定位方案

获取原文
获取原文并翻译 | 示例
           

摘要

This study aimed to investigate an improved setup protocol for maintaining patient setup accuracy, with minimal or no use of image-guided radiation therapy in conventional radiotherapy for lung cancer. A coordinate value for the treatment couch in the anterior-posterior (AP) direction was obtained from the first fraction using bony anatomy image guidance. The coordinate value was invariably used for patient positioning in the second and subsequent treatment fractions. The errors of 2410 setup image sets (anterior and lateral) from 105 patients with lung cancer were analyzed. The systematic and random patient positioning errors in the AP direction were 0.6 ±1.0 mm. Such errors accounted for 97% of all fractions within ± 2 mm. The protocol resulted in minimal patient setup errors in the AP direction using only one image for guidance; therefore, it may be applied to conventional radiotherapy for lung cancer in case of insufficient image guidance.
机译:本研究旨在调查用于维持患者设置精度的改进的设置方案,具有最小的或不使用在肺癌中传统放射治疗的图像引导放射治疗。 使用骨骼解剖图像引导从第一部分获得前后(AP)方向上的处理沙发的坐标值。 坐标值总是用于患者定位在第二和随后的治疗级分中。 分析了105例肺癌患者的2410设置图像集(前后和横向)的误差。 AP方向上的系统和随机患者定位误差为0.6±1.0mm。 此类误差占±2毫米的所有分数的97%。 该协议在AP方向上产生最小患者设置错误,仅使用一个图像进行指导; 因此,在图像引导不足的情况下,它可以应用于肺癌的常规放射治疗。