The purpose of this study was to compare between superparamagnetic iron oxide (SPIO)-enhanced three-dimensional balanced turbo field-echo (B-TFE) sequence with T_2 preparation pulse (T_2 prep) and T_2*-weighted imaging (T_2*WI) for the simultaneous detection of hepatocellular carcinoma (HCC) and vessel thrombus. For 1.5-T magnetic resonance imaging, SPIO was administered to 23 patients with a portal or venous tumor thrombus, and B-TFE with T_2 prep and T_2*WI were acquired. Regions of interest in the B-TFE and T_2*WI were selected for the tumor, liver, tumor thrombus, and vessels. The contrasts of the HCC in the liver and the tumor thrombus in the vessels were determined from clinical image. Contrast was calculated using the mean value of the signal intensity on the HCC to the liver and tumor thrombus to vessels.
机译:本研究的目的是通过T_2制备脉冲(T_2PREP)和T_2 * -wiighted成像(T_2 * Wi)在超顺磁性氧化铁(SPIO) - 纳米型氧化铁(SPIO) - 纳米型三维平衡涡轮场 - 回波(B-TFE)序列之间进行比较 同时检测肝细胞癌(HCC)和血管血栓。 对于1.5-T磁共振成像,将SPIO施用至23例门静脉或静脉肿瘤血栓,并获得了具有T_2准备和T_2 * Wi的B-TFE。 选择B-TFE和T_2 * Wi的兴趣区域用于肿瘤,肝,肿瘤血栓和血管。 从临床上确定血管中HCC在肝脏中的对比和血管中的肿瘤血栓。 使用HCC对肝脏和肿瘤血栓的信号强度的平均值计算对比。