Comparison of Skinfold Thicknesses and Bioimpedance Spectroscopy to Dual-Energy X-Ray Absorptiometry for the Body Fat Measurement in Patients With Chronic Kidney Disease

机译:乳头厚度和生物敏捷光谱对慢性肾病患者体脂测量的双能X射线吸收测量的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background/Objectives: The aim of the study was to compare the amount of body fat measured by skinfold thickness (SFT) and bioimpedance spectroscopy (BIS) with dual-energy x-ray absorptiometry (DXA) as a reference method. Methods: Forty-eight patients undergoing hemodialysis treatment thrice-weekly for at least 3 months (HD group) with a mean age of 59.8 +/- 15.5 years, 61 patients with chronic kidney disease (CKD) with an estimated glomerular filtration rate (eGFR) <30 mL/min/1.73 m(2) and a mean age of 60.1 +/- 17.7 years (predialysis group, PreD), and 33 individuals without kidney disease with an eGFR >60 mL/min/1.73 m(2) and a mean age of 58.7 +/- 17.0 years (control group) were included. Results: Mean percentages of body fat measured by SFT did not significantly differ from those measured by DXA in the HD group (P = .249) and the PreD group (P = .355). In the control group, mean percentage of fat mass measured by SFT was significantly higher than measured by DXA (P = .004). Mean difference was 1.99% +/- 3.65%. The measurements of body fat performed by BIS were significantly higher than those performed by DXA in all studied groups (P < .001). Age was statistically significant and the strongest factor that influenced the variability of measurements obtained by BIS and DXA in all studied groups (R-2 = 0.302, 0.153, and 0.250, respectively, for HD, PreD, and control groups). Conclusions: SFT as a method of fat mass assessment in daily routine practice seems to be more reliable then BIS in patients treated with hemodialysis and in patients with stage IV/V CKD. However, methods based on bioimpedance techniques can potentially offer more data such as overhydration or an amount of lean tissue mass, but further investigations are needed to establish method the most suitable for patients with CKD.
机译:背景/目标:该研究的目的是将通过皮屑厚度(SFT)和生物阻抗光谱(BIS)测量的体脂量与双能X射线吸收测量法(DXA)作为参考方法进行比较。方法:48名患者接受血液透析治疗,每周至少3个月(HD组),平均年龄为59.8 +/- 15.5岁,61例慢性肾病(CKD)具有估计的肾小球过滤速率(EGFR )<30ml / min / 1.73 m(2)和平均年龄为60.1 +/- 17.7岁(预依旧组,pred)和33名没有肾病的人,EGFR> 60ml / min / 1.73 m(2)包括平均年龄为58.7 +/- 17.0岁(对照组)。结果:SFT测量的体脂的平均百分比与HD组中DXA测量的体脂没有显着差异(P = .249)和PEAT组(P = .355)。在对照组中,SFT测量的脂肪质量的平均百分比显着高于DXA测量(P = .004)。平均差异为1.99%+/- 3.65%。 BIS表演的体脂的测量显着高于所有研究组中的DXA(P <.001)。年龄是统计学上的显着性,并且影响所有研究组(R-2 = 0.302,0.153和0.250分别用于HD,PREA和对照组)中BIS和DXA获得的测量变异性的最强因素。结论:SFT作为日常常规实践中的脂肪量评估的方法似乎更可靠,然后在血液透析和阶段IV / v CKD患者治疗的患者中是更可靠的。然而,基于生物阻抗技术的方法可能提供更多的数据,例如过度水合或瘦组织物质的量,但需要进一步的研究来建立最适合CKD患者的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号