首页> 外文期刊>Nuclear Medicine Communications >The utility of the combination of a SPECT study with [I-123]-FP-CIT of dopamine transporters and [I-123]-MIBG myocardial scintigraphy in differentiating Parkinson disease from other degenerative parkinsonian syndromes
【24h】

The utility of the combination of a SPECT study with [I-123]-FP-CIT of dopamine transporters and [I-123]-MIBG myocardial scintigraphy in differentiating Parkinson disease from other degenerative parkinsonian syndromes

机译:SPECT研究与[I-123]的效用与[I-123] -FP-CIT的多巴胺转运蛋白和[I-123] -MIBG心肌闪烁扫描从其他退化的帕金森综合征区分帕金森病

获取原文
获取原文并翻译 | 示例
           

摘要

ObjectiveMolecular imaging of nigrostriatal dopamine transporters (DAT) and sympathetic cardiac innervation with single-photon emission computed tomography (SPECT) are useful tools for differentiating idiopathic Parkinson disease (PD) from other degenerative parkinsonian syndromes (non-PD). Nevertheless, these modalities are often insufficient for achieving a definite diagnosis. The aims of this study were to evaluate the diagnostic accuracy of the combination of these tools.Materials and methodsThe SPECT radiotracers [I-123]-N--fluoropropyl-2-carbomethoxy-3-(4-iodophenyl)-nortropane (FP-CIT) and meta-[I-123]-iodobenzylguanidine (MIBG) were used to research presynaptic dopaminergic projections (DAT SPECT) and myocardial adrenergic innervation (MIBG scintigraphy), respectively. PD patients (n=15; age: 61.513.6 years) and non-PD patients (n=19; age: 62.614.2 years) who underwent both tests were enrolled in this study. Receiver-operating characteristic analyses were used to set the cutoff values of the specific binding ratio in DAT SPECT and the heart to mediastinum ratio in delayed scan in MIBG scintigraphy for differentiating PD from non-PD. We calculated the sensitivity, specificity, and test accuracy of the individual methods and also the combination of these two modalities.ResultsWhen DAT SPECT and MIBG scintigraphy were used individually, they showed mild accuracy in differentiating PD from non-PD (DAT, 67.6%; MIBG, 67.6%). The combination of the two approaches using cutoff values of less than 3.24 for the specific binding ratio and less than 2.745 for the delayed heart to mediastinum ratio enabled more accurate differentiation between PD and non-PD. The accuracy of these indices in distinguishing PD from non-PD was 79.4%.ConclusionThese results suggested that the combination of DAT SPECT and MIBG scintigraphy may improve the diagnostic accuracy in differentiating PD from non-PD.
机译:具有单光子发射计算机断层扫描(SPECT)的纽粒状多巴胺转运蛋白(DAT)和交感神经支配的客体成像是用于区分特发性帕金森病(PD)的有用工具(非PD)。然而,这些方式通常不足以实现明确的诊断。本研究的目的是评估这些工具组合的诊断准确性。材料和方法SPECT放射反射液[I-123] -N-氟丙基-2-碳甲氧基-3-(4-碘苯基) - 丙烷(FP- CIT)和META- [I-123] - 碘苄基胍(MIBG)分别用于研究突触前的多巴胺能突起(DAT SPECT)和心肌肾上腺素能内膜(MIBG SCINTIGRAPHY)。 PD患者(n = 15;年龄:61.513.6岁)和非PD患者(n = 19;年龄:62.614.2岁)均参加这项研究。接收器操作特征分析用于将DAT SPECT中的特异性结合比的截止值与MIBG SCINTIGRAWAMARHY中的延迟扫描中的常量粘合剂与非Pd分化为分化。我们计算了各种方法的灵敏度,特异性和测试精度以及这两个模态的组合。培养韦伦DAT SPECT和MIBG Scintigraphy单独使用,它们表现出轻微的精度,在非Pd(DAT,67.6%)中的PD差异化精度。 MIBG,67.6%)。对于特异性结合率小于3.24的两种方法的组合对于延迟心脏延迟,对纵隔的比率小于2.745,使PD和非Pd之间的更精确分化能够实现。在非Pd中区分Pd的这些指标的准确性为79.4%。结论这些结果表明,DAT SPECT和MIBG Scintigraphy的组合可以提高来自非Pd的分化Pd的诊断准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号