Shortened acquisition time in simultaneous Tc-99m-tetrofosmin and I-123-beta-methyl-p-iodophenyl pentadecanoic acid dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction

机译:在接受急性心肌梗死的初级冠状动脉介入的患者中,缩短了与镉 - 锌 - 碲化镉探测器的捕获时间和I-123-β-甲基-P-碘苯戊己戊二酸双跟踪剂的缩短时间

获取原文
获取原文并翻译 | 示例
           

摘要

Objective The use of cadmium-zinc-telluride-based scanners may increase the clinical feasibility of simultaneous dual-isotope imaging. In the current study, we sought to investigate a potential acquisition time in simultaneous Tc-99m-tetrofosmin/I-123-beta-methyl-p-iodophenyl pentadecanoic acid dual-isotope imaging using a Discovery NM/CT 670 cadmium-zinc-telluride. Methods Simultaneous Tc-99m-tetrofosmin/I-123-beta-methyl-p-iodophenyl pentadecanoic acid dual-isotope imaging was performed in 29 patients who had undergone primary percutaneous coronary intervention for acute myocardial infarction. Referenced images with an acquisition time of 65 s/view (16.25 min) were reframed to produce images with acquisition times of 33, 16, and 8 s/view. The values for the quantitative-gated single-photon emission computed tomography (SPECT) and the quantitative perfusion SPECT were compared. Results The quantitative-gated SPECT values for images with 33, 16, and 8 s/views showed good consistency with those for 65 s/view (the lower 95% confidence intervals for the intraclass correlation were >= 0.80). The quantitative perfusion SPECT values for Tc-99m-tetrofosmin images with 33, 16, and 8 s/views also showed good consistency with those for 65 s/view; however, the quantitative perfusion SPECT values for I-123-beta-methyl-p-iodophenyl pentadecanoic acid images with an acquisition time of 8 s/view were not consistent with the reference acquisition time of 65 s/view. Conclusions The quantitative-gated SPECT and quantitative perfusion SPECT values obtained from images with shorter acquisition times correlated with the values obtained from images with a reference acquisition time of 65 s/view; however, tracer-specific predisposition should be considered. These findings suggest that it is possible to reduce acquisition time when performing simultaneous Tc-99m-tetrofosmin/I-123-beta-methyl-p-iodophenyl pentadecanoic acid dual-tracer imaging with the novel cadmium-zinc-telluride scanner.
机译:目的利用镉 - 锌 - 碲化物的扫描仪可能增加同时双同位素成像的临床可行性。在目前的研究中,我们试图使用Discovery NM / CT 670镉 - 碲化物在同时探讨同时TC-99M-Tetroofosmin / I-123-β-β-碘苯基戊二烷酸双同位素成像的潜在捕集时间。方法同时进行TC-99M-四氟哌胍/ I-123-β-甲基-P-碘苯磺酰戊二酸双同位素成像于29例经过急性心肌梗死的主要经皮冠状动脉介入。 Recabled I / View的获取时间(16.25分钟)的引用图像被重新规定,以产生33,16和8 S /视图的采集时间。比较了定量门控单光子发射计算断层扫描(SPECT)和定量灌注SPECT的值。结果33,16和8 S /视图的图像的定量门控SPECT值显示出良好的一致性与65秒/视图(较低的95%置信区间隔> = 0.80)。具有33,16和8 s /视图的TC-99M-四孢素图像的定量灌注SPECT值还显示出良好的一致性与65秒/次观察;然而,具有8 s /视图的获取时间的I-123-β-甲基-P-碘苯苯基戊烷戊烷戊烯磺酸图像的定量灌注SPECT值与65秒/视图的参考获取时间不一致。结论从图像中获得的定量门控SPECT和定量灌注SPECT值与较短的获取时间相关的图像与从图像获得的图像中获得的值为65秒/视图;但是,应考虑特定于特定的倾向。这些发现表明,在用新型镉 - 锌 - 碲化酰胺扫描仪进行同时进行同时TC-99M-Tetroofosmin / I-123-β-甲基 - 碘苯基 - 碘苯甲酸双示踪剂成像时可以降低采集时间。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号