首页> 外文期刊>Aesthetic plastic surgery >The influence of external ultrasound on the histologic architecture of the organic capsule around smooth silicone implants: experimental study in rats.
【24h】

The influence of external ultrasound on the histologic architecture of the organic capsule around smooth silicone implants: experimental study in rats.

机译:外部超声对光滑硅胶植入物周围有机胶囊组织学结构的影响:在大鼠中的实验研究。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules. METHODS: In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into "ultrasound" and "control" groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained withhematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light. RESULTS: Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization. CONCLUSION: The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.
机译:背景:囊膜挛缩症是与乳房硅胶植入物有关的主要并发症,其预防仍然是一项医学挑战。作者们进行了实验研究,研究了外部超声对种植体周围囊形成和挛缩的影响。方法:在这项研究中,对42只雄性Wistar大鼠进行了2毫米光滑表面植入物的植入,该植入物位于背部肌肉下袋中。然后将它们分为“超声波”和“对照组”,在开启或不开启超声波电源的情况下接受重复的外部应用。每周进行3次超声波应用,持续90天。此后,两组都被安排在相同的条件下,没有安排任何申请。每组五只动物分别在第30、60、90和180天被杀死,他们的植入物与胶囊一起被移除,它们通过环形切片接受了特殊的组织学准备,可以对囊膜组织进行广泛的周向观察。将切片用苏木精/曙红染色,Masson三色染色和Pricrosirius Red染色进行染色,以便在正常和偏振光下进行常规显微镜评估。结果:组织学数据显示,超声组和对照组的胶囊有统计学差异。超声应用开发了一种与有纹理的有机硅植入物相似的囊状结构,其效果具有早期定义,并具有后续的稳定性。结论:作者得出结论,早期和反复使用外部超声可以增加光滑的硅胶囊组织的厚度,细胞计数和血管性,同时减少胶原纤维平行取向的模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号