首页> 外文期刊>Blood coagulation & fibrinolysis: an international journal in haemostasis and thrombosis >Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease.
【24h】

Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease.

机译:新型自动von Willebrand因子活性测定法与聚集von Willebrand ristocetin辅助因子活性测定法用于诊断von Willebrand疾病的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

von Willebrand disease (VWD) is caused by quantitative and/or qualitative defects of von Willebrand factor (VWF). The HemosIL von Willebrand Factor Activity assay, a new automated immunological test to measure VWF activity, was implemented on STAC and compared with the von Willebrand ristocetin cofactor activity (VWF:RCo) aggregation method. Imprecision and dilution studies were also performed.Within-run imprecision was 17.2% and between-run imprecision was 8.3% (coefficients of variation). Dilution studies showed a linearity between 12.5 and 100%.Passing and Bablok regression comparing the HemosIL von Willebrand Factor Activity assay and the aggregation method yielded a slope of 1.25 (95% confidence interval: 1.11-1.38) and intercept of -1.40 (95% confidence interval: -8.07 to 0.00). The correlation coefficient was 0.84 (95% confidence interval: 0.78-0.89).With a cut-off value of 50% for VWF activity, the assay has a sensitivity of 94.1% and a specificity of 92.8%, compared with the VWF:RCo aggregation assay with a cut-off value of 60% producing a sensitivity of 100.0% (specificity 87.6%).With a cut-off value of 60%, the HemosIL von Willebrand Factor Activity assay on STAC is a reliable assay for VWD. VWF:RCo or other functional testing is still required to confirm the diagnosis and for further classification of VWD.
机译:von Willebrand病(VWD)是由von Willebrand因子(VWF)的定量和/或定性缺陷引起的。在STAC上进行了HemosIL von Willebrand因子活性测定法,这是一种测量VWF活性的新型自动免疫测试方法,并与von Willebrand ristocetin辅因子活性(VWF:RCo)聚集方法进行了比较。还进行了不精确度和稀释度研究,分析中不精确度为17.2%,分析间不准确度为8.3%(变异系数)。稀释研究显示12.5%至100%之间的线性。通过HemosIL von Willebrand因子活性分析和聚集方法比较的Passing和Bablok回归得出的斜率为1.25(95%置信区间:1.11-1.38),截距为-1.40(95%)置信区间:-8.07至0.00)。相关系数为0.84(95%置信区间:0.78-0.89).VWF活性的截断值为50%,与VWF:RCo相比,该方法的灵敏度为94.1%,特异性为92.8%。截断值为60%的聚合检测可产生100.0%的灵敏度(特异性为87.6%)。截断值为60%的STAC的HemosIL von Willebrand因子活性检测是VWD的可靠检测方法。仍需要VWF:RCo或其他功能测试以确认诊断和VWD的进一步分类。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号