首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy
【24h】

More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy

机译:可以使用开放式高胫骨截骨术中的三维印刷模型获得更精确的校正

获取原文
获取原文并翻译 | 示例
           

摘要

PurposeThe purpose of this study was to compare the accuracy of the preoperative planning method using a three-dimensional (3D) printed model with that of a method using picture archiving and communication system (PACS) images in high tibial osteotomy (HTO).MethodsPatients who underwent HTO using a 3D printed model (20 patients) and a method based on PACS images (20 patients) from 2012 to 2016 were compared. After obtaining the correction angle, in the 3D printed method, the wedge-shaped 3D printed model was designed. The PACS method used preoperative radiographs. The accuracy of HTO for each method was compared using radiographs obtained at the first postoperative year. The preoperative and postoperative posterior tibial slope angles were also compared.ResultsThe weight-bearing line was corrected 21.211.8% from preoperatively to 61.63.3% postoperatively in the 3D group and from 19.4 +/- 12.3% to 61.3 +/- 8.1% in the PACS group. The mean absolute difference with the target point was lower in the 3D group (2.3 +/- 2.5) than in the PACS group (6.2 +/- 5.1; p=0.005). The number of patients in an acceptable range was higher in the 3D group than in the PACS group. The posterior tibial slope angle was not significantly different in the 3D group (8.6 degrees-8.9 degrees), but was significantly different in the PACS group (9.9 degrees-10.5 degrees, p=0.042).ConclusionsIn open-wedge HTO, a more accurate correction for successful results could be obtained using the 3D printed model.Level of evidenceIV.
机译:本研究的目的的目的是比较使用三维(3D)印刷模型的术前规划方法的准确性,其中使用高胫骨截骨术(HTO)中使用图像归档和通信系统(PACS)图像的方法。方法比较了使用3D印刷模型(20名患者)和基于PACS图像(20名患者)2012年至2016年的方法的HTO。在获得校正角后,在3D打印方法中,设计了楔形的3D印刷模型。 PACS方法使用术前射线照片。使用在第一术后年份获得的射线照片进行比较每种方法的HTO的准确性。比较术前和术后后胫骨斜角。术后轴承线在3D组中术后术前校正为21.211.8%,从19.4 +/-12.3%才能校正21.211.8%至61.6.3%至61.3 +/- 8.1%在PACS组。 3D组(2.3 +/- 2.5)的平均绝对差异低于PACS组(6.2 +/- 5.1; p = 0.005)。 3D组中可接受范围内的患者的数量比PACS组在PACS组中较高。 3D胫骨斜角在3D组(8.6度-8.9度)中没有显着差异,但在PACS组(9.9度-10.5度,P = 0.042)中显着不同.Clclusionsin开放式HTO,更准确可以使用3D打印模型获得成功结果的校正。有线电器的3D。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号