In this paper venturimeter is proposed to measure the flow rate of homogeneous solid-liquid two-phase flows in a tube at low volume concentrations. Six mixtures varying in concentration and velocity were systemically measured in both horizontal and vertical arrangements for the variations of pressure and discharge coefficient of venturi. The results show that the average discharge coefficient ratio is positively related to concentration. However the growth rate decreases as concentration increases, and the maximum of the former is merely 1.05 times the minimum when concentration varied from 0% to 15%. Furthermore the average discharge coefficient ratio decreases as the particle size increases for the same concentration, whose maximum value increase by 3%. The results indicate that venturi is an accurate meter for homogeneous solid-liquid two-phase flow measurement. (C) 2019 Elsevier Ltd. All rights reserved.
机译:在本文中,提出了在低体积浓度下测量管中均匀固液两相流量的流速。 在水平和垂直布置中系统地测量浓度和速度变化的六种混合物,用于文丘里的压力和放电系数的变化。 结果表明,平均放电系数比与浓度正相关。 然而,随着浓度的增加,生长速率降低,而前者的最大值仅仅是浓度为0%至15%的最小值的1.05倍。 此外,随着粒度的增加,平均放电系数比随着相同的浓度增加,其最大值增加3%。 结果表明,文丘里是用于均匀固液两相流量测量的精确仪表。 (c)2019年elestvier有限公司保留所有权利。