Comparison of Circumference Body Composition Measurements and Eight-Point Bioelectrical Impedance Analysis to Dual Energy X-Ray Absorptiometry to Measure Body Fat Percentage

机译:圆周体成分测量和八点生物电阻抗分析对双能X射线吸收测量体脂百分比的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background: To compare the circumference measurement (CM) body composition method and 8-point segmental bioelectrical impedance analysis (DSM-BIA) to dual energy X-ray absorptiometry (DEXA) in military members. Objective: The objective was to compare three body composition methods. Our hypothesis was the CM is as accurate as DSM-BIA and DEXA in assessing body fat percentage (%BF). Design: Cross sectional, observational study. Participants/Setting: Healthy active duty military males and nonpregnant females. Seventy-six participants (mean age 35.0 +/- 9.7 years, mean body mass index 28.9 +/- 4.7 kg/m(2)), outpatient clinic setting was used. Statistical Analyses: Agreement between DEXA and the other two methods was examined using an intraclass correlation coefficient (ICC) using the two-way random method with absolute agreement. Repeated measures analysis of covariance was used to examine the effect of gender and waist circumference on differences in %BF. Results: The agreement of DSM-BIA with DEXA for females was ICC = 0.93 (95% confidence interval [CI]: 0.87-0.96) and for males, ICC = 0.89 (95% CI: 0.78-0.94). For the agreement of CM with DEXA, the ICC for females was 0.83 (95% CI: 0.71-0.91) and for males the ICC = 0.72 (95% CI: 0.49-0.85). For females with smaller waists ( = 95.3 cm), the DSM-BIA overestimated the DEXA measurement by a mean of 2.6% (95% CI: 0.9-4.3%). For females with larger waists (>= 81.3 cm), the CM overestimated the DEXA %BF by an average of 2.4% (95% CI: 0.7-4.1%). Conclusion: There was good agreement between the three methods assessed in this study. Both waist circumference and gender had an effect on the accuracy of the DSM-BIA and CM measurements.
机译:背景:将圆周测量(CM)体组成方法和8点节段性生物电阻抗分析(DSM-BIA)与军事成员的双能X射线吸收仪(DEXA)进行比较。目的:目的是比较三种身体成分方法。我们的假设是CM与DSM-BIA和DEXA在评估体脂百分比(%BF)中是准确的。设计:横截面,观察研究。参与者/环境:健康的活性军事男性和非妊娠女性。七十六参与者(平均年龄为35.0 +/- 9.7年,平均体重指数28.9 +/- 4.7 kg / m(2)),使用门诊诊所设置。统计分析:使用具有绝对协议的双向随机方法,使用具有绝对协议的双向随机方法来检查DEXA和其他两种方法之间的协议。反复措施的协方差分析用于检查性别和腰围对%BF差异的影响。结果:DSM-BIA与女性DEXA的协议是ICC = 0.93(95%置信区间[CI]:0.87-0.96)和雄性,ICC = 0.89(95%CI:0.78-0.94)。对于CM与DEXA的协议,女性的ICC为0.83(95%CI:0.71-0.91),并且为雄性ICC = 0.72(95%CI:0.49-0.85)。对于较小的腰部的女性(= 95.3厘米),DSM-BIA的均值高估为2.6%(95%CI:0.9-4.3%)。对于具有较大腰部的女性(> = 81.3cm),CM高估了DEXA%BF,平均为2.4%(95%CI:0.7-4.1%)。结论:本研究评估的三种方法之间存在良好的一致性。两种腰围和性别都对DSM-BIA和CM测量的准确性产生了影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号