首页> 外文期刊>Mapan: Journal of Metrology Society of India >Attenuation Scale Calibration of an Optical Time Domain Reflectometer Using an External Laser Source
【24h】

Attenuation Scale Calibration of an Optical Time Domain Reflectometer Using an External Laser Source

机译:使用外部激光源的光学时域反射计的衰减比例校准

获取原文
获取原文并翻译 | 示例
           

摘要

Optical time domain reflectometers (OTDRs) are widely used to measure the attenuation of optical fibers. Accurate measurement of the attenuation requires periodic calibration of OTDRs. In this paper, a system is proposed based on the external source method (ESM) to calibrate of the attenuation scale of an OTDR over a dynamic range of around 15?dB. The ESM method has several advantages over the widely-used standard reference fiber (SRF) since it is fast, can be automated and offers direct traceability to the SI units. In order to estimate the accuracy of the proposed setup, an OTDR has been calibrated using the SRF and the ESM methods. The calibration uncertainty of the ESM method is found to be 0.040?dB, which is similar to that of the SRF method which is found to be 0.038?dB.
机译:光学时域反射计(OTDRS)被广泛用于测量光纤的衰减。 准确测量衰减需要OTDR的定期校准。 在本文中,基于外部源方法(ESM)来提出一个系统,以校准OTDR在大约15b的动态范围内校准OTDR的衰减量表。 由于快速,ESM方法具有多于广泛使用的标准参考光纤(SRF)的优点,可以自动化,并为SI单元提供直接可追溯性。 为了估计所提出的设置的准确性,使用SRF和ESM方法校准OTDR。 ESM方法的校准不确定度被发现为0.040?DB,其类似于发现为0.038的SRF方法的DB。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号