This study presented a biosafety device for the hygienic storage of composite resin during restorative procedures in teaching clinics, RESTAURASAFE, and to compare the color stability, surface hardness, and degree of conversion of the composite resin made with the proposed device to those of conventionally made resins. Esthet-X HD composite was manipulated directly from the syringe, fractionated doses, dappen dish or RESTAURASAFE. Disc-shaped specimens were immersed in artificial saliva and coffee for 60 days and the color stability and the Vickers surface hardness were evaluated during 60 days. Degree of conversion was assessed after immersing specimens in saliva (baseline). The surface morphology analysis of composite resin has taken by scanning electron microscopy (SEM). The data were evaluated statistically by repeated measures ANOVA (alpha=.05). No difference of color stability was observed for saliva and coffee regardless of storing devices. The resin manipulated directly from the syringe presented lower hardness, and fractionated doses presented lower degree of conversion than the RESTAURASAFE. SEM analysis showed that after artificial aging in coffee for 60 days, the specimens prepared with fractionated doses of resin displayed the fewest changes in surface morphology, followed by those prepared with the RESTAURASAFE. We conclude that RESTAURASAFE allows to obtain similar color stability, higher hardness, and degree of conversion of the composite in comparison to the other storing devices.
机译:该研究介绍了在教学诊所,Restaurasafe中的恢复程序中卫生储存的生物安全装置,并比较了用所提出的装置制成的复合树脂的颜色稳定性,表面硬度和转化程度的常规制造的颜色稳定性,表面硬度和转化程度树脂。 ESTHET-X HD复合材料直接从注射器,分级剂量,Dappen Dish或RestauraSafe操纵。将盘形标本浸入人工唾液中,咖啡60天,在60天期间评价颜色稳定性和维氏表面硬度。在浸入唾液(基线)的样本后评估转化程度。复合树脂的表面形态学分析通过扫描电子显微镜(SEM)捕获。通过重复测量ANOVA(alpha = .05)统计评估数据。无论储存装置如何,对于唾液和咖啡就没有观察到颜色稳定性的差异。直接从注射器操纵的树脂呈现较低的硬度,并且分级剂量呈现比餐饮饮料更低的转化程度。 SEM分析表明,在咖啡中的人工老化60天后,用分馏剂量的树脂制备的样品显示出表面形态最少的变化,其次是用餐饮饮料制备的那些。我们得出结论,与其他存储装置相比,Restabasafe允许获得类似的颜色稳定性,更高的硬度和复合材料的转换程度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号