【24h】

A fluorescent probe composed of quantum dot labeled aptamer and graphene oxide for the determination of the lipopolysaccharide endotoxin

机译:由标记为适体和氧化石墨烯的量子点组成的荧光探针,用于测定脂多糖内毒素

获取原文
获取原文并翻译 | 示例
       

摘要

Endotoxins are complex lipopolysaccharides (LPS) and key components of the outer cell membrane of Gram-negative bacteria. The authors report on a fluorescent aptamer-based probe for the determination ofLPS of Gram-negative bacteria. An aptamer against LPS was fluorescently labeled with CdSe/ZnS quantum dots. Its emission is quenched on addition of graphene oxide (GO). On addition of LPS, the aptamer binds LPS and GO is released. This results in the recovery of fluorescence, typically measured at excitation/emission wavelengths of 495/543nm. The probe responds to LPS in the 10-500ngmL(-1) concentration range, and the detection limit is 8.7ngmL(-1). It can be used for selective detection of LPS from different Gram-negative bacteria, in the presence of biological interferents.Schematic presentation of a greenfluorescent probe comprised of an aptamer labelled withCdSe/ZnS quantum dots and ofgraphene oxide. Lipopolysaccharides bind to the aptamer and release graphene oxide to result in fluorescence recovery, which is measured at anemission wavelength 543nm.
机译:内毒素是复杂的脂多糖(LPS)和革兰氏阴性细菌的外部细胞膜的关键部件。作者报告了基于荧光适体的探针,用于测定革兰氏阴性细菌。针对LPS的适体被CDSE / ZnS量子点荧光标记。通过添加石墨烯(GO)淬火其排放。添加LPS,Aptamer结合LPS并释放出来。这导致荧光的恢复,通常在495 / 543nm的激发/发射波长下测量。探针在10-500ngml(-1)浓度范围内响应LPS,检测限为8.7ngmm(-1)。它可以用于从不同革兰氏阴性细菌中选择性检测来自不同革兰氏阴性细菌的LPS,在生物干预率存在下。化学探针的化学介绍,该探针包含标记的适体/ ZnS量子点和俄语氧化物。脂多糖与适体和释放石墨烯氧化物结合,导致荧光回收,这在易溶波长543nm处测量。

著录项

相似文献

  • 外文文献
  • 中文文献