Stapedectomy versus stapedotomy.

机译:骨切除术与骨切开术。

获取原文
获取原文并翻译 | 示例
           

摘要

Four hundred and twelve consecutive stapes operations for otosclerosis performed by the author were analyzed. A fat wire stapedectomy prosthesis (Schuknecht) was used in 160 cases and a Fisch Teflon wire piston in 252 ears. Ninety-four percent of the patients with a fat wire prosthesis had a closure within 10 dB and the remaining 6% one within 10-20 dB. As for patients with a Fisch Teflon wire piston, 85% had a closure within 10 dB, and 98-100% within 0-20 dB. Speech reception was better after the operation in 97% of patients with the fat wire prosthesis and in 99% of patients having the Teflon wire piston. There was a significantly different improvement in speech reception (p < 0.02) at the 20-dB level in favor of the Teflon wire piston. Our results show that the small fenestra technique with a 0.4-mm piston causes better speech reception at high frequencies.
机译:分析了作者连续进行的412例骨硬化骨手术。 160例患者使用了脂肪丝骨切除术假体(Schuknecht),252耳中使用了Fisch Teflon钢丝活塞。 94%的带有脂肪金属丝假体的患者的闭合度在10 dB以内,其余6%的患者在10-20 dB以内。对于使用Fisch Teflon线活塞的患者,85%的闭合度在10 dB以内,98-100%的闭合度在0-20 dB以内。手术后97%的脂肪金属丝假体患者和99%的特氟龙金属丝活塞患者的语音接收效果更好。有利于使用特富龙金属丝活塞,在20 dB的水平下,语音接收的改善显着不同(p <0.02)。我们的结果表明,采用0.4毫米活塞的小型fenestra技术可在高频下更好地接收语音。