首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Simultaneous determination of ultra-trace level Np-237 and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation
【24h】

Simultaneous determination of ultra-trace level Np-237 and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation

机译:通过单柱色谱分离通过SF-ICP-MS同时测定土壤和沉积物样品中的超痕量NP-237和PU同位素

获取原文
获取原文并翻译 | 示例
           

摘要

This work presents a method developed for simultaneous analysis of ultra-trace level Np-237 and Pu isotopes in soil and sediment samples by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Pu-242 was used as a yield tracer for Np-237 as well as for Pu isotopes. A simple single chromatographic column packed with anion exchange resin (AG MP-1M) was used for the separation of Np-237 and Pu isotopes from the matrix elements and other potential interferences. The SF-ICP-MS measurement precision of the Np-237/Pu-242 atom ratio for sub-fg/mL level Np-237 and (PU)-P-242 was 0.97%, and the overall fractionation between Np-237 and (PU)-P-242 for the whole analysis procedure was 1.010 +/- 0.038. Besides, the single column chromatographic separation realized high decontamination factor of U (1.8 x 10(6) to 1.7 x 10(7)), and that ensured the interference effect of U-238 to the Np-237, Pu-239 and Pu-240 measurements was negligible or could be easily corrected. Four standard reference materials were analyzed for method validation, and the results illustrated Pu-242 was an effective non-isotopic tracer for Np-237 determination. Finally, the developed method was successfully employed in the analysis of the global fallout level of Np-237 and Pu isotopes in Japanese paddy soil samples to study their environmental behaviors.
机译:该工作提出了一种用于通过扇区电感耦合等离子体质谱(SF-ICP-MS)同时分析土壤和沉积物样本中的超痕量NP-237和PU同位素的方法。 PU-242用作NP-237以及PU同位素的产率示踪剂。用阴离子交换树脂(Ag MP-1M)填充的简单单个色谱柱用于从基质元件和其他潜在干扰中分离NP-237和PU同位素。 SUP-237 / PU-242原子比的SF-ICP-MS测量精度为亚FG / mL水平NP-237和(PU)-P-242的0.97%,以及NP-237和NP-237之间的总分馏(PU)-P-242整体分析程序为1.010 +/- 0.038。此外,单柱色谱分离实现了U(1.8×10(6)至1.7×10(7))的高净化因子,并确保了U-238到NP-237,PU-239和PU的干扰效果-240测量可忽略不计或可以很容易地校正。分析了四种标准参考材料进行方法验证,结果说明了PU-242是NP-237测定的有效非同位素示踪剂。最后,在日本水稻土样品中的NP-237和PU同位素的全球辐射水平分析中成功地使用了开发方法,以研究其环境行为。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号