In this study, a new and efficient analytical method was developed to determine hexavalent chromium, Cr (VI), in water by flame atomic absorption spectrometry (FAAS). This method consists on the simultaneous selective extraction and preconcentration of Cr (VI) in water by dispersive solid phase extraction (DSPE), using Zn-Al layered double hydroxide intercalated with L-Alanine (ZnAl-ALA-LDH) as adsorbent. Experimental parameters that influence Cr (IV) determination efficiency, such as pH, time and interfering ions were studied and optimized. After selective extraction of Cr (VI) in the presence of Cr (III) at pH 5.2, ZnAl-ALA-LDH was dissolved in H2SO4 5 mol.L-1. An interesting property of this material is its immediate dissolution at pH values below 3. The complete ZnAl-ALA-LDH dissolution after adsorption ensured that all Cr (VI) adsorbed was analyzed by FAAS, dispensing the use of eluents during the process and thus decreasing the extraction time. In addition to the selective extraction of Cr (VI), the method also allowed sensitivity increase and interference reduction by pre-concentration. Calibration was linear in the range of 20 to 700 mu g.L-1 (r(2) > 0.99). The limits of detection (LOD) and quantification (LOQ) were 7.1 mu g.L-1 and 23.6 mu g.L-1, respectively. Relative standard deviation (RSD) was 2.7% (n = 10). The method accuracy was verified by analyzing a certified water containing Cr (VI) (Cr (VI)-QC1453) and recovery studies on drinking water samples.
机译:在该研究中,开发了一种新的和高效的分析方法以通过火焰原子吸收光谱法(FAAS)测定水中的六价铬Cr(VI)。该方法包括通过分散固相萃取(DSPE)的分散固相萃取(DSPE)在水中同时选择性提取和前浓缩,其使用用L-丙氨酸(Znal-Ala-LDH)相插为吸附剂。研究了影响Cr(iv)测定效率的实验参数,例如pH,时间和干扰离子。在pH5.2的Cr(III)存在下选择性提取Cr(vi),Znal-Ala-LDH溶解在H 2 SO 4 5mol.L-1中。这种物质的有趣性质是其在低于3的pH值的立即溶解3.吸附后的完全Znal-Ala-LDH溶解确保通过FAAS分析吸附的所有Cr(VI),在该过程中分配了洗脱液的使用,从而降低提取时间。除了Cr(VI)的选择性提取之外,该方法还允许通过预浓度增加敏感性增加和干扰。校准在20至700μmG1-1(R(2)> 0.99)的范围内。检测限(LOD)和定量(LOQ)分别为7.1μg-1和23.6μg1-1。相对标准偏差(RSD)为2.7%(n = 10)。通过分析含Cr(vi)(Cr(vi)-qc1453)和饮用水样品的恢复研究来验证方法准确度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号