首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Development of a needle trap device packed with zinc based metal-organic framework sorbent for the sampling and analysis of polycyclic aromatic hydrocarbons in the air
【24h】

Development of a needle trap device packed with zinc based metal-organic framework sorbent for the sampling and analysis of polycyclic aromatic hydrocarbons in the air

机译:用基于锌金属有机框架吸附剂堆积的针阱装置的研制,用于空气中多环芳烃的取样和分析

获取原文
获取原文并翻译 | 示例
       

摘要

This study aimed to present a new method combined of needle trap devices (NTDs) packed with the Zn-3(BTC)(2) metal-organic framework (Zn-MOF) as a sorbent, for the sampling and analysis of polycylic aromatic hydrocarbons (PAHs) in the air for the first time. The electrochemical method was used to synthesize Zn-MOF sorbent packed inside 22 gauge needle trap. This method was investigated in the laboratory under different condition and applied in the field to determination of PAHs in air. In order to make different concentrations of PAHs in air, a glass chamber under temperature of 120 degrees C was used. The optimization of the desorption conditions and breakthrough volume was accomplished using the response surface method and Design-Expert software (version 7). According to the results, the best desorption temperature was obtained as 379 degrees C in 9 min, the limit of detection and limit of quantification for the analytes under investigation were within the ranges of 0.011-0.021 and 0.03-0.07 mg/m(3), respectively. Moreover, repeatability and reproducibility of the method were estimated in the ranges of 3.6-9.9 and 5.3-24.1, respectively. By storing the needles at 4 degrees C, no significant reduction was observed in the amount of analytes after 60 days (P > 0.05). It could be concluded that NTD: Zn-MOF is a reliable and high collection efficiency method had a suitable performance in the sampling of PAHs, compared to the National Institute for Occupational Safety and Health (NIOSH)-5515 method.
机译:本研究旨在提出一种新的方法,其与Zn-3(BTC)(2)金属 - 有机骨架(Zn-MOF)填充的针阱装置(NTDS)作为吸附剂,用于聚芳烃的取样和分析(PAHS)第一次在空中。电化学方法用于合成填充在22号针阱内的Zn-Mof吸附剂。在不同条件下的实验室中研究了该方法,并在现场应用于测定空气中的PAHS。为了在空气中进行不同浓度的PAH,使用温度为120℃的玻璃室。使用响应面方法和设计 - 专家软件(版本7)完成解吸条件和突破量的优化。根据结果​​,在9分钟内获得最佳解吸温度为379摄氏度,检测中的分析物的检测极限和定量限制在0.011-0.021和0.03-0.07 mg / m(3)的范围内。 , 分别。此外,该方法的可重复性和再现性分别估计了3.6-9.9和5.3-24.1的范围。通过在4摄氏度下储存针,在60天后在分析物量中没有显着降低(P> 0.05)。可以得出结论,NTD:Zn-MOF是一种可靠,高收集的效率方法在PAHS的采样中具有适当的性能,而与国家职业安全和健康研究所(NIOSH)-5515方法相比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号