首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >A dual-mode colorimetric and SERS detection of hydrogen sulfide in live prostate cancer cells using a silver nanoplate-coated paper assay
【24h】

A dual-mode colorimetric and SERS detection of hydrogen sulfide in live prostate cancer cells using a silver nanoplate-coated paper assay

机译:使用银纳米载体涂布纸法测定,双模比色和活硫化氢硫化氢检测

获取原文
获取原文并翻译 | 示例
       

摘要

We report a simple and facile paper assay based on silver nanoplates (Ag NPls) for the colorimetric and surface-enhanced Raman scattering (SERS) dual-mode detection of hydrogen sulfide (H2S) gas released from live cancer cells. Ag NPls were prepared via seed-mediated growth and dropped on detection zones within the poly(dimethylsiloxane)-patterned paper substrate. The blue-colored Ag NPls on the paper react with H2S to form browncolored silver sulfide, which simultaneously decreases SERS activity of Ag NPls. We quantitatively analyzed the color and Raman signal intensity changes in Ag NPl-coated detection zone on the paper, using the parameter b of L*a*b color space and Raman peak at 1356 cm(-1) of Rhodamine B, respectively. As a result, our Ag NPl-coated H2S dual-sensing paper assay showed a good sensitivity with a linear range of 1.64-16.4 mu M H2S and a detection limit of 520 nM for colorimetric detection. And, it also represented a high sensitivity with a linear range of 82-330 nM H2S for SERS detection. In addition, it possessed high selectivity, excellent reproducibility, and high stability over 1 month. Using this Ag NPl-coated H2S dual sensing paper, we successfully measured the H2S concentration in live prostate cancer cells at different incubation times and cell numbers. Therefore, the Ag NPl-coated paper assay can be utilized as a facile and effective tool for the dual-mode colorimetric and SERS detection of free H2S gas within live cells without complicated sample processing or labor-intensive bioanalytical methods.
机译:我们报告了基于银纳米板(Ag NPLS)的简单和容易的纸张测定,用于从活癌细胞释放的硫化氢(H2S)气体的硫化氢(H2S)气体的硫化氢和表面增强的拉曼散射(SERS)双模检测。通过种子介导的生长制备Ag NPL,并在聚(二甲基硅氧烷) - 涂料纸基材内的检测区上滴下。纸上的蓝色Ag NPLS与H2S反应形成棕色墨硫化物,同时降低Ag NPLs的SERs活性。我们使用L * A * B颜色空间的参数B和1356cm(-1)的Rhodamine B分别在纸张上定量分析了Ag NPL-涂覆的检测区中的颜色和拉曼信号强度变化。结果,我们的AG NPL-涂覆的H2S双传感纸测定显示出良好的灵敏度,线性范围为1.64-16.4 mu m H 2 S和用于比色度检测的520nm的检测限。并且,它还代表了具有82-330nm H2S的线性范围的高灵敏度,用于SERS检测。此外,它具有高选择性,优异的再现性和1个月的高稳定性。使用该AG NPL-涂覆的H2S双传感纸,我们在不同孵育时间和细胞数中成功地测量了直播前列腺癌细胞中的H2S浓度。因此,Ag NPL-涂布纸测定可以用作用于双模比色测量的容易和有效的工具,并在没有复杂的样品处理或劳动密集型生物分析方法的活细胞内的自由H 2 S气体检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号