首页> 外文期刊>Metrology and Measurement Systems: Metrologia i Systemy Pomiarowe >UV-VIS SPECTROSCOPIC DETECTION COUPLED WITH CHEMOMETRICS FOR THE MEASUREMENT OF MIXED ORGANIC ACIDS IN WATER SAMPLES ENRICHED BY RADIAL ELECTRIC FOCUSING SOLID PHASE EXTRACTION
【24h】

UV-VIS SPECTROSCOPIC DETECTION COUPLED WITH CHEMOMETRICS FOR THE MEASUREMENT OF MIXED ORGANIC ACIDS IN WATER SAMPLES ENRICHED BY RADIAL ELECTRIC FOCUSING SOLID PHASE EXTRACTION

机译:UV-Vis光谱检测与化学计量学相结合,用于测量由径向电光聚焦固相萃取富集的水样中的混合有机酸

获取原文
获取原文并翻译 | 示例

摘要

Due to the difficulty of detecting traces of organic acid mixture in an aqueous sample and the complexity of resolving UV-Vis spectra effectively, a combinatory method based on a self-made radical electric focusing solid phase extraction (REFSPE) device, UV-Vis detection and partial least squares (PLS) calculation is proposed here. In this study, REFSPE was used to enhance the extraction process of analytes between the aqueous phase and the membrane phase to enrich the trace of mixed organic acid efficiently. Then, the analytes, which were eluted from the adsorption film by ethanol with the assistance of an ultrasonic cleaning machine, were detected with UV-Vis spectrophotometry. After that, the PLS method was introduced to solve the problem of overlapping peaks in UV-Vis spectra of mixed substances and to quantify each compound. The linearly dependent coefficients between the predicted value of the model and the actual concentration of the sample were all higher than 0.99. The limit values of detection for benzoic acid, phthalic acid and p-toluene sulfonic acid were found at 9.9 μg/L, 12.2 μg/L and 13.8 μg/L with the relative recovery values between 84.8% and 117.9%. The RSD (n = 20) values of each component are 1.17%, 1.11% and 0.86%, respectively. Therefore, the proposed combined method can determine traces of complex materials in an aqueous sample efficiently and has wonderful potential applications.
机译:由于难以在水性样品中检测有机酸混合物的痕量和有效分辨uV-VIS光谱的复杂性,一种基于自制自由基电聚焦固相萃取(REFSPE)装置,UV-Vis检测的组合方法此处提出了局部最小二乘(PLS)计算。在该研究中,Refspe用于增强水相和膜相之间分析物的提取过程,以有效富集混合有机酸的痕量。然后,用UV-Vis分光光度法检测通过乙醇从吸附膜洗脱的分析物,通过UV-Vis分光光度法检测到超声波清洗机。之后,引入PLS方法以解决混合物质的UV-Vis光谱中的重叠峰的问题并定量每种化合物。模型的预测值与样品的实际浓度之间的线性相关系数均高于0.99。发现苯甲酸,邻苯二甲酸和对甲苯磺酸的检测的极限值为9.9μg/ L,12.2μg/ L和13.8μg/ L,相对恢复值在84.8%和117.9%之间。每个组分的RSD(n = 20)值分别为1.17%,1.11%和0.86%。因此,所提出的组合方法可以有效地测定含水样品中的复合物质的痕量并具有精彩的潜在应用。

著录项

  • 来源
  • 作者单位

    Tianjin Polytechnic University School of Environmental and Chemical Engineering Tianjin 300387 China;

    Tianjin Polytechnic University School of Environmental and Chemical Engineering Tianjin 300387 China;

    Tianjin Polytechnic University School of Environmental and Chemical Engineering Tianjin 300387 China;

    Tianjin Polytechnic University State Key Laboratory of Separation Membranes and Membrane Processes Tianjin 300387 China;

    Tianjin Polytechnic University State Key Laboratory of Separation Membranes and Membrane Processes Tianjin 300387 China;

    Tianjin Polytechnic University State Key Laboratory of Separation Membranes and Membrane Processes Tianjin 300387 China;

    Tianjin Polytechnic University State Key Laboratory of Separation Membranes and Membrane Processes Tianjin 300387 China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 计量学;
  • 关键词

    chemo-metrics; UV-Vis spectrophotometer; radial electric focusing solid phase extraction; mixed organic acids;

    机译:化学指标;UV-Vis分光光度计;径向电光聚焦固相萃取;混合有机酸;