首页> 外文期刊>Materiale Plastice >Bipolar Polyethylene Radial Head Artroplasty in Posttraumatic Unstable Elbows Prosthetic design and clinical results
【24h】

Bipolar Polyethylene Radial Head Artroplasty in Posttraumatic Unstable Elbows Prosthetic design and clinical results

机译:双极聚乙烯桡骨头射击术在后期不稳定的肘部假肢设计和临床结果

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this experimental study is to present the design and biomechanical characteristics of bipolar polyethylene radial head prostheses type KPS (CHM (R) Poland), as well as to evaluate their use in comminuted fractures type Mason III associated with ligament injuries. We retrospectively evaluated 7 patients with 7 complex radial head fractures with an average age of 38.5 years. The prostheses were implanted through a lateral Kocher approach and patients immediately began the rehabilitation of the elbow. The functional results according to the MEPS score (Mayo Elbow Performance Score) were excellent in 3 cases and good in 4 cases, without stem loosening or residual instability of the elbow. Due to the overwhelming advantages of this bipolar prosthesis (better joint tracking and easier implantation technique) and its very good functional results, the authors recommend this type of arthroplasty in posttraumatic elbow instability.
机译:该实验研究的目的是呈现双极聚乙烯径向头部假体型KPS(CHM(R)波兰)的设计和生物力学特性,以及评估其在与韧带损伤相关的粉碎骨折型Mason III中的用途。 我们回顾性评估了7例患有7例7种复杂的径向头部骨折,平均年龄为38.5岁。 通过横向kocher方法植入假体,患者立即开始弯曲弯头的康复。 根据MEPS评分(Mayo肘部性能评分)的功能结果在4例中优异,4例良好,没有杆松动或肘部的残余不稳定性。 由于这种双极假肢的压倒性优势(更好的关节跟踪和更容易植入技术)及其非常良好的功能结果,提交人建议这种类型的关节造形术在创始的肘部不稳定中。