...
首页> 外文期刊>Magnetic resonance in medicine: official journal of the Society of Magnetic Resonance in Medicine >Vascular input function correction of inflow enhancement for improved pharmacokinetic modeling of liver DCE DCE ‐ MRI MRI
【24h】

Vascular input function correction of inflow enhancement for improved pharmacokinetic modeling of liver DCE DCE ‐ MRI MRI

机译:血管输入功能校正流入增强改善肝脏DCE的药代动力学建模 - MRI MRI

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To propose a simple method to correct vascular input function (VIF) due to inflow effects and to test whether the proposed method can provide more accurate VIFs for improved pharmacokinetic modeling. Methods A spoiled gradient echo sequence‐based inflow quantification and contrast agent concentration correction method was proposed. Simulations were conducted to illustrate improvement in the accuracy of VIF estimation and pharmacokinetic fitting. Animal studies with dynamic contrast‐enhanced MR scans were conducted before, 1 week after, and 2 weeks after portal vein embolization (PVE) was performed in the left portal circulation of pigs. The proposed method was applied to correct the VIFs for model fitting. Pharmacokinetic parameters fitted using corrected and uncorrected VIFs were compared between different lobes and visits. Results Simulation results demonstrated that the proposed method can improve accuracy of VIF estimation and pharmacokinetic fitting. In animal study results, pharmacokinetic fitting using corrected VIFs demonstrated changes in perfusion consistent with changes expected after PVE, whereas the perfusion estimates derived by uncorrected VIFs showed no significant changes. Conclusion The proposed correction method improves accuracy of VIFs and therefore provides more precise pharmacokinetic fitting. This method may be promising in improving the reliability of perfusion quantification. Magn Reson Med 79:3093–3102, 2018. ? 2017 International Society for Magnetic Resonance in Medicine.
机译:目的提出一种简单的方法来纠正血管输入功能(VIF)由于流入效应,并测试所提出的方法是否可以为改进的药代动力学建模提供更准确的VIF。方法提出了一种腐蚀性梯度回波序列的流入量化和造影剂浓度校正方法。进行了模拟以说明VIF估计和药代动力学配合的准确性的提高。用动态对比增强MR扫描的动物研究在猪的左门口循环中进行1周后,在门静脉栓塞(PVE)后2周进行。应用了该方法以校正模型配件的VIFS。在不同的裂片和访问之间比较使用校正和未校正VIFS的药代动力学参数。结果仿真结果表明,该方法可以提高VIF估计和药代动力学配件的准确性。在动物研究结果中,使用校正VIFS的药代动力学配件证明了PVE后预期的变化的灌注变化,而通过未校正的VIFs衍生的灌注估计显示没有显着的变化。结论所提出的校正方法提高了VIFS的准确性,因此提供了更精确的药代动力学配件。该方法可以提高灌注量化的可靠性。 Magn Reson Med 79:3093-3102,2018 2017年医学磁共振的国际社会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号