Purpose To develop a respiratory motion correction framework to accelerate free‐breathing three‐dimensional (3D) whole‐heart coronary lumen and coronary vessel wall MRI. Methods We developed a 3D flow‐independent approach for vessel wall imaging based on the subtraction of data with and without T2‐preparation prepulses acquired interleaved with image navigators. The proposed method corrects both datasets to the same respiratory position using beat‐to‐beat translation and bin‐to‐bin nonrigid corrections, producing coregistered, motion‐corrected coronary lumen and coronary vessel wall images. The proposed method was studied in 10 healthy subjects and was compared with beat‐to‐beat translational correction (TC) and no motion correction for the left and right coronary arteries. Additionally, the coronary lumen images were compared with a 6‐mm diaphragmatic navigator gated and tracked scan. Results No significant differences ( P ??0.01) were found between the proposed method and the gated and tracked scan for coronary lumen, despite an average improvement in scan efficiency to 96% from 59%. Significant differences ( P ??0.01) were found in right coronary artery vessel wall thickness, right coronary artery vessel wall sharpness, and vessel wall visual score between the proposed method and TC. Conclusion The feasibility of a highly efficient motion correction framework for simultaneous whole‐heart coronary lumen and vessel wall has been demonstrated. Magn Reson Med 77:1894–1908, 2017. ? 2016 International Society for Magnetic Resonance in Medicine
机译:目的开发呼吸运动校正框架,加速自由呼吸的三维(3D)全心冠状腔和冠状动脉壁MRI。方法我们开发了基于与图像导航器的交错器的数据的减法的基于数据的减法的血管壁成像的3D流动独立方法。所提出的方法将数据集校正了使用搏击击败翻译和垃圾箱非校正的相同呼吸位置,生产重铸,运动矫正冠状内腔和冠状动脉壁图像。该方法在10个健康的受试者中研究了该方法,并与击败搏动转化校正(TC)进行了比较,左右冠状动脉的运动校正。另外,将冠状动脉腔图像与6mm隔膜导航仪进行进行比较和跟踪扫描。结果在所提出的方法和冠状内腔的所提出的方法和跟踪扫描之间发现了显着差异(p?&Δ01),尽管扫描效率平均提高至59%的96%。在右冠状动脉血管壁厚,右冠状动脉壳壁锐度,右冠状动脉堵塞和血管壁视觉得分和TC之间发现了显着差异(p≤01.01)。结论已经证明了同时全心冠状动脉腔和血管壁的高效运动校正框架的可行性。 Magn Reson Med 77:1894-1908,2017 2016国际医学磁共振学会

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号