首页> 外文期刊>Malaria research and treatment >Cost-Effectiveness and Validity Assessment of Cyscope Microscope, Quantitative Buffy Coat Microscope, and Rapid Diagnostic Kit for Malaria Diagnosis among Clinic Attendees in Ibadan, Nigeria
【24h】

Cost-Effectiveness and Validity Assessment of Cyscope Microscope, Quantitative Buffy Coat Microscope, and Rapid Diagnostic Kit for Malaria Diagnosis among Clinic Attendees in Ibadan, Nigeria

机译:尼日利亚Ibadan,尼日利亚诊所与临床参与者诊所诊断中的患者显微镜,定量胃癌显微镜和快速诊断试剂盒的成本效益

获取原文
获取原文并翻译 | 示例
           

摘要

Background. Unavailability of accurate, rapid, reliable, and cost-effective malaria diagnostic instruments constitutes major a challenge to malaria elimination. We validated alternative malaria diagnostic instruments and assessed their comparative cost-effectiveness. Method. Using a cross-sectional study design, 502 patients with malaria symptoms at selected health facilities in Ibadan between January and April 2014 were recruited consecutively. We examined malaria parasites using Cyscope?, QBC, and CareStart? and results were compared to light microscopy (LM). Validity was determined by assessing sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Costs per hour of use for instruments and turnaround time were determined. Result. Sensitivity of the instruments was 76.0% (CareStart), 95.0% (Cyscope), and 98.1% (QBC). Specificity was 96.0% (CareStart), 87.3% (Cyscope), and 85.5% (QBC). PPV were 65.2%, 67.5%, and 84.7%, while NPV were 93.6%* 98.6%, and 99.4% for CareStart, Cyscope, and QBC with Kappa values of 0.75 (CI = 0.68-0.82) for CareStart, 0.72 (CI = 0.65-0.78) for Cyscope, and 0.71 (CI = 0.64-0.77) for QBC. Average cost per hour of use was the lowest ($2.04) with the Cyscope. Turnaround time was the fastest with Cyscope (5 minutes). Conclusion. Cyscope fluorescent microscope had the shortest turnaround time and is the most cost-effective of all the malaria diagnostic instruments evaluated.
机译:背景。无需准确,快速,可靠,经济高效的疟疾诊断仪器构成了对疟疾消除的主要挑战。我们验证了替代疟疾诊断工具,并评估了他们的比较成本效益。方法。使用横断面研究设计,2014年1月至4月在2014年1月至4月之间选择的疟疾症状502例疟疾症状,连续招募。我们使用综合素寄生虫检查疟疾寄生虫,QBC和CARESTART?并将结果与​​光学显微镜(LM)进行比较。通过评估敏感性,特异性,阳性预测值(PPV)和负预测值(NPV)来确定有效性。确定了仪器和周转时间使用每小时的成本。结果。仪器的敏感性为76.0%(Carestart),95.0%(综合型)和98.1%(QBC)。特异性为96.0%(Carestart),87.3%(综合型)和85.5%(QBC)。 PPV为65.2%,67.5%和84.7%,而NPV为Carestart的Kappa值为0.75(CI = 0.68-0.82)的93.6%* 98.6%,99.4%,QBC为0.75(CI = 0.68-0.82)0.72(CI = 0.65-0.78)对于QBC的综合型和0.71(CI = 0.64-0.77)。使用每小时的平均成本是最低(2.04美元),综合杂散。周转时间是患有综合型的最快(5分钟)。结论。综合荧光显微镜具有最短的周转时间,是评估所有疟疾诊断仪器的最具成本效益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号