首页> 外文期刊>BJU international >Wiedemann, L.a , Cornu, J.-N.a , Haab, E.a , Peyrat, L.a , Beley, S.a , Cathelineau, X.b c , Haab, F.a Transcorporal artificial urinary sphincter implantation as a salvage surgical procedure for challenging cases of male stress urinary incontinence: Surgical technique and functional outcomes in a contemporary series
【24h】

Wiedemann, L.a , Cornu, J.-N.a , Haab, E.a , Peyrat, L.a , Beley, S.a , Cathelineau, X.b c , Haab, F.a Transcorporal artificial urinary sphincter implantation as a salvage surgical procedure for challenging cases of male stress urinary incontinence: Surgical technique and functional outcomes in a contemporary series

机译:Wiedemann,La,Cornu,J.-Na,Haab,Ea,Peyrat,La,Beley,Sa,Cathelineau,Xb c,Haab,Fa进行人工体括约肌植入术作为针对男性压力性尿失禁的具有挑战性病例的抢救性手术方法:当代系列的手术技术和功能结局

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives To describe the surgical technique of transcorporal artificial urinary sphincter (AUS) implantation. To assess the efficacy of the AUS on continence and erectile function. Patients and Methods A prospective evaluation was conducted between December 2007 and October 2012 at a tertiary referral centre of all male patients treated by transcorporal AUS (AMS800?, AmericanMedicalSystems, Minnetonka, MN, USA) implantation for stress urinary incontinence (SUI) recurrence, after failure of previous anti-incontinence surgery. Functional urinary outcomes were assessed according to daily pad use, the Urinary Symptom Profile questionnaire, and International Consultation on Incontinence Questionnaire - Short-Form. Erectile function was evaluated using the five-item International Index of Erectile Function (IIEF-5) questionnaire and patient satisfaction was assessed by Patient Global Impression of Improvement questionnaire. Data were collected by telephone interview. Results A total of 23 patients were included. Their mean (sd; range) age was 70 (7; 60-85) years. Of these, 18 patients had urethral atrophy and/or erosion after placement of AUS (11 patients), male sling (four patients) or both (three patients), and five patients had severe urethral atrophy after pelvic radiation therapy. The implantation of the AUS with transcorporal cuff placement was successful in all patients, with no peri-operative complications. Follow-up data over 1 year were available for 17 patients. After a median (sd; range) follow-up of 20 (15; 2-59) months, eight patients were perfectly dry (no pad use and no symptoms), five achieved social continence (less than one pad/day), and four still had SUI (required two or more pads/day). Among six patients who had good preoperative erectile function and were sexually active, four had no decrease in their IIEF-5 score. Conclusions Transcorporal AUS cuff placement is a useful alternative for challenging cases of male SUI after failure of previous surgical treatment, urethral atrophy or erosion. Erectile function can be maintained despite dissection of the corporal body.
机译:目的描述经体人工尿道括约肌(AUS)植入的手术技术。评估AUS对节制和勃起功能的疗效。患者和方法在2007年12月至2012年10月之间,对所有经经体AUS(AMS800?,AmericanMedicalSystems,Minnetonka,MN,美国)植入的男性患者的三级转诊中心进行了前瞻性评估,以评估其术后压力性尿失禁(SUI)复发的可能性。先前的抗失禁手术失败。根据每日使用尿垫,尿道症状概况调查表和失禁问卷国际咨询(简表)评估功能性尿路结局。使用五项国际勃起功能指数(IIEF-5)问卷评估勃起功能,并通过“患者总体印象改善”问卷评估患者满意度。通过电话采访收集数据。结果共纳入23例患者。他们的平均年龄(sd;范围)为70(7; 60-85)岁。在这些患者中,有18例在放置AUS后出现尿道萎缩和/或糜烂(11例),雄性吊带(4例)或两者(3例),还有5例在盆腔放疗后出现严重的尿道萎缩。在所有患者中,经体囊套入的AUS植入均成功,无围手术期并发症。有1位患者1年以上的随访数据。在中位(sd;范围)随访20(15; 2-59)个月后,八名患者完全干燥(无垫使用,无症状),五名患者实现了社交自控(少于一垫/天),并且四个仍然具有SUI(每天需要两个或多个打击垫)。在术前勃起功能良好且有性活动的6例患者中,有4例的IIEF-5评分未降低。结论经体外AUS袖套放置对于在先前手术治疗失败,尿道萎缩或糜烂后具有挑战性的男性SUI病例是一种有用的选择。尽管体液解剖,仍可维持勃起功能。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号