...
首页> 外文期刊>European archives of oto-rhino-laryngology: Official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) >Dyna-CT of the temporal bone for case-specific three-dimensional rendering of the stapedial muscle for planning of electrically evoked stapedius reflex threshold determination during cochlear implantation directly from the stapedius muscle via a retrofacial approach: a pilot study
【24h】

Dyna-CT of the temporal bone for case-specific three-dimensional rendering of the stapedial muscle for planning of electrically evoked stapedius reflex threshold determination during cochlear implantation directly from the stapedius muscle via a retrofacial approach: a pilot study

机译:用于颞骨的DYNA-CT,以用于齿盒肌肉的特异性三维渲染,用于通过转接方法直接从Stapedius肌肉直接从Stapedius肌肉进行耳蜗植入术后的旋转肌肉:试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose Evaluation of 3D Dyna-CTs to improve cochlear implantation (CI) planning and intraoperative electricallyelicited stapedius reflex threshold (ESRT) measurements. Methods A prospective observational cohort study was performed. Anonymized data collection of Dyna-CTs and CI surgeries in which a retrofacial approach was implemented to access the stapedius muscle. 3D Dyna-CTs of 30 patients and the intraoperative confirmation of the predication in 5/30 patients during CI surgery were evaluated. Inter-rater reliability was also analyzed along with the predictive value of this evaluation. Results 36 representative structures of the middle and inner ear and 3D renderings of the Dyna-CTs were evaluated by four otoneurological surgeons. Fleiss' kappa values for the evaluation of the visibility were high (> 0.7) for most of the anatomical structures. The stapedius muscle was visible in 90% of the cases. Using the 3D data, the retrofacial access to the stapedius muscles was estimated as feasible in 86.7%. Fleiss' kappa value of the evaluation of the accessibility was 0.942. The intraoperative exploration of the stapedius muscle confirmed the preoperative prediction in all five selected patients (four patients with predicted accessibility and one patient with predicted inaccessibility). Conclusions The use of Dyna-CT and 3D rendering is a helpful tool for preoperative planning of cochlear implantations and ESRT measurements from the stapedius muscle via the retrofacial approach.
机译:3D DYNA-CTS改善耳蜗植入(CI)规划和术中闪电术Stapedius Reflex阈值(ESRT)测量的目的评价。方法进行预期观察队列研究。 Dyna-CTS和CI手术的匿名数据收集,其中实施了一种转裂方法以进入Stapedius肌肉。评估了30名患者的3D DYNA-CTS和CI手术期间5/30患者预测的术中确认。还分析了帧间的可靠性以及该评估的预测值。结果通过四个耳科外科医生评估DYNA-CTS的中耳和内耳和3D渲染的36个代表性结构。对于大多数解剖结构,对可见性评估的Fleiss Kappa值高(> 0.7)。在90%的病例中,Stapedius肌肉可见。使用3D数据,对STAPEDIUS肌肉的出口接入估计在86.7%中可行。 FALISS KAPPA值的可访问性评估为0.942。 Stapedius肌肉的术中探索证实了所有五种选定患者的术前预测(四名预期可访问性和一个预测可接受的患者)。结论使用Dyna-CT和3D渲染的使用是一种有用的工具,用于通过再涂层方法从Stapedius肌肉的术术植入和ESRT测量的术前规划。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号