...
首页> 外文期刊>European archives of oto-rhino-laryngology: Official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) >A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance
【24h】

A systematic review of current methodology of high resolution pharyngeal manometry with and without impedance

机译:具有智能阻抗的高分辨率咽部测压方法的系统综述

获取原文
获取原文并翻译 | 示例
           

摘要

PurposeThis systematic review appraises and summaries methodology documented in studies using high resolution pharyngeal manometry (HRM) with and without impedance technology (HRIM) in adult populations.MethodsFour electronic databases CINAHL, EMBASE, MEDLINE, and Cochrane Library were searched up to, and including March 2017. Studies reporting pharyngeal HRM/HRIM for swallowing and/or phonatory assessment, published in peer-reviewed journals in English, German, or Spanish were assessed for the inclusion criteria. Of the selected studies, methodological aspects of data acquisition and analysis were extracted. Publications were graded based on their level of evidence and quality of methodological aspects was assessed.ResultsSixty-two articles were identified eligible, from which 50 studies reported the use of HRM and 12 studies used HRIM. Of all included manuscripts, the majority utilized the ManoScan system (64.5%), a catheter diameter of 4.2mm was most prevalently documented (30.6%). Most publications reported the application of topical anesthesia (53.2%). For data analysis in studies using HRM, software intrinsic to the recording system was reported most frequently (56%). A minority of the studies using HRM provided data about measurement reliability (10%). This is higher for studies using HRIM (50%).ConclusionsConsiderable methodological variability exists regarding data acquisition and analysis in published studies using HRM/HRIM. Lacking reports of methodology make study replications difficult and reduce the comparability across studies. More data regarding the impact of individual methodological aspects on study outcomes are further required for the development of methodological recommendations.
机译:在使用高分辨率咽部测量(HRM)的研究中,在成人群体中使用高分辨率咽部测量(HRM)的研究中记录和摘要方法。研究了电力数据库Cinahl,Embase,Medline和Cochrane图书馆,包括3月份2017年。报告临床HRM / HRIM用于吞咽和/或口音评估的吞咽和/或忏悔评估,用于纳入标准的同行审查的期刊上发表。在所选择的研究中,提取数据采集和分析的方法论方面。出版物的评分是根据他们的证据水平和方法论的质量评估。鉴定了鉴定了50项研究的方法,从中鉴定了使用HRM和12项使用HRIM的研究。在所有包括的手稿中,大多数利用ManoScan系统(64.5%),导管直径为4.2mm,最普遍记录(30.6%)。大多数出版物报告局部麻醉的应用(53.2%)。对于使用HRM的研究中的数据分析,最频繁地报告了记录系统的软件内因(56%)。使用HRM的少数研究提供了有关测量可靠性的数据(10%)。使用HRIM(50%)的研究更高缺乏方法论的报道使研究复制困难并降低研究的可比性。更多需要有关各种方法论对研究结果的影响的更多数据,以便制定方法论建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号