摘要

Purpose: The aim of this study was to evaluate the intraobserver reproducibility of demarcation line depth measurement in keratoconic patients after epithelium-off corneal collagen cross linking and assess the interobserver variability/agreement among examiners of various experience levels. Methods: 56 eyes of 56 patients undergoing corneal collagen cross linking for progressive keratoconus were enrolled. After 4 weeks, all patients underwent an anterior segment optical coherence tomography (AS-OCT; CASIA SS-1000; Tomey, Nagoya, Japan) in the cross-linked eye by four masked examiners (two medical students (S1 and S2) and two corneal fellows (F1 and F2)) in order to identify and measure the demarcation line depth in experienced and non-experienced users. The intraclass correlation coefficient and the coefficient of variation were calculated. Agreement between raters was evaluated using Bland-Altman plots, intraclass correlation coefficient and weighted-kappa statistics comparing raters in pairs. Results: The average demarcation line depth of all measurements was 254.34 +/- 72.3 mu m, varying from 84 to 459 mu m. The intraclass correlation coefficient evaluating the reproducibility of measurements for F1 was 0.9379 (95% confidence interval (CI) =0.9035-0.9619), for the second (F2), it was 0.9837 (95% confidence interval = 0.9743-0.9901), while intraclass correlation coefficient between medical students was calculated 0.844. The overall intraclass correlation coefficient among all four observers was 0.8706 (95% confidence interval = 0.8061-0.9185). The coefficient of variation for repeated measurements was 5.981 mu m (95% confidence interval = 3.966-7.471) and 3.312 mu m (95% confidence interval = 2.468-3.981) for F1 and F2 raters, respectively. The percentage of demarcation line detection was 90.32%. Conclusion: The reproducibility of demarcation line measures although very good (intraclass correlation coefficient > 0.9), yielded a difference between the two experienced raters. Furthermore, the novice raters did not reach an excellent level of agreement with the expert ones showing greater variability in their recordings.
机译:目的:本研究的目的是评估木质角膜胶原蛋白交联后角灭绝患者分界线深度测量的血管内的再现性,并评估各种经验水平审查员的interobserver变异性/协议。方法:参加了56例接受角膜胶原蛋白交叉连接的56名患者进行了进步的角膜蛋白酶。 4周后,所有患者都经历了前段光学相干断层扫描(AS-OCT; Casia SS-1000; Tomey,Nagoya,日本)在交联眼中,四个蒙面的审查员(两个医学生(S1和S2)和两个角膜研究员(F1和F2))为了识别和衡量经验丰富的用户的分界线深度。计算腹积相关系数和变异系数。使用Bland-Altman绘图评估评估评估者之间的协议,腹部相关系数和加权-Kappa统计数据成对比较评估者。结果:所有测量的平均分界线深度为254.34 +/- 72.3亩,从84到459 mu m不同。评估F1测量的再现性的脑内相关系数为0.9379(95%置信区间(CI)= 0.9035-0.9619),为第二(F2),为0.9837(95%置信区间= 0.9743-0.9901),同时颅内计算医学生与0.844之间的相关系数。所有四个观察者中的整体腹积相关系数为0.8706(95%置信区间= 0.8061-0.9185)。重复测量的变化系数分别为5.981μm(95%置信区间= 3.966-7.471)和3.312μm(95%置信区间= 2.468-3.981),分别用于F1和F2评估者。分界线检测的百分比为90.32%。结论:分界线措施的再现性虽然非常好(腹积相关系数> 0.9),但两种经验的评估者之间产生了差异。此外,新手评估者没有达到优秀的协议水平,专家们在录音中表现出更大的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号